2. Connecting the device 
 Myth  Preamplifier  is  intended  for  use  in  close  and  dry  environment. 
Surrounding of the device must be clean and dry. 
 The operating temperature is from 5 C to 50 C. Storage temperature is 
from -10 C to 60 C. 
 The device is using city AC power network 240V/50Hz. 
 The  device  is  protected  with  the  fuse  of  1.16A  at  the  primary  of  the 
mains transformer. In case of necessity, the fuse should be replaced only 
with the appropriate type for 1.16A (F 1.16A) 
 The backside switch puts the device in stand-by state. 
 The control lamp on the switch indicates that the mains cable contains 
a  proper  grounding.  In  the  case  the  lamp  is  off  it  is  recommended  to 
check the grounding connection of the mains cable before using it. 
 Device  chassis  is  grounded  via  mains  cable.  Analog  grounds  of  RCA 
connectors are not grounded. 
 It  is  recommended  to  avoid  connecting  and  disconnecting  RCA  cables 
while  the  device  is  turned  on.  This  may  cause  noise  and  interference  to 
the  power  amplifier,  thus  making  unpleasant  noise  on  the  system 
speakers. The safest way to connect RCA cables is to completely power off 
the device and then to attach desired connectors. 
 The back panel of the Myth Preamplifier provides five stereo line inputs 
and one stereo line output. 