Operation Manual
CONDITION POSSIBLE CAUSES POSSIBLE SOLUTIONS
No power. • The power cord is disconnected. • Plug the power cord into the wall outlet
securely.
• POWER switch set to OFF position. • Set the POWER switch to ON position.
C 275BEE always at standby mode;
cannot be switched ON using the
front panel STANDBY button.
• +12V TRIGGER IN/INPUT SENSE switch set to “AUTO”
position.
• Slide the +12V TRIGGER IN/INPUT SENSE
switch to “OFF” position.
No sound. • Power AC lead unplugged or power not switched ON. • Check if AC lead is plugged-in and POWER
switched ON (along with the corresponding
ATO logic conguration).
• No input signal applied through the INPUT sockets. • Check that there is active input signal
applied through the INPUT sockets.
• INPUT LEVEL CONTROL turned down. • Turn INPUT LEVEL CONTROL up to the
correct level.
No sound one channel. • Speaker not properly connected or damaged. • Check connections and speakers.
• Input lead disconnected or damaged. • Check leads and connections.
Weak bass/diused stereo image. • Speakers wired out of phase. • Check connections to all speakers in the
system.
POWER/STANDBY LED stays red
upon turning POWER ON.
• There is short circuit in the speaker cabling. • Switch C 275BEE OFF and check speaker
cable connections for both speaker terminals
at the rear panel.
REFERENCE
TROUBLESHOOTING
10
ENGLISH FRANÇAIS ESPAÑOL ITALIANO DEUTSCH NEDERLANDS SVENSKA РУССКИЙ