User Manual

AUTO STANDBY
Auto Standby feature is an integral feature of C 368 that conforms to
European ecodesign regulations. The C 368 can be setup to automatically
go to standby mode if there is no user interface interaction and no active
source input within 20 minutes.
ON
C 368 switches to standby mode at lowest power consumption (less
than 0.5W) if there is no user interface interaction and no active source
input within 20 minutes.
OFF
C 368 remains at operating mode even if there is no user interface
interaction and no active source within 20 minutes.
Refer also to table below about “OPERATING MODE TRIGGER POINTS”.
AUTO SENSE
Auto sense feature enables the C 368 to wake up from standby mode
when triggered by network connected App or active source input.
ON
Unit wakes up from standby mode when triggered by network
connected App or active source input.
Except for analog input, the unit will power up to the Source that
activated the unit to operating mode.
When the unit is triggered by an active analog input, the unit will
always power up to Line 1.
OFF
Unit remains at standby mode even if it is triggered by network
connected App or active source input.
Refer also to table below about “OPERATING MODE TRIGGER POINTS”.
OPERATING MODE TRIGGER POINTS
SETTINGS OPERATING MODE TRIGGER
Auto Standby: On
Network Standby: On
Auto Sense: On
Unit switches back to operating mode by
resuming activity at network connected app.
an active source input.
pressing front panel Standby button or SR 9 remote
control’s [ON] button.
Auto Standby: On
Network Standby: O
Auto Sense: On
Unit switches back to operating mode by
an active source input.
pressing front panel Standby button or SR 9 remote
control’s [ON] button.
Auto Standby: On
Network Standby: On/O
Auto Sense: O
Unit remains at standby mode even if it is triggered
by network connected App or active source input.
Unit can only be switched back to operating mode by
pressing front panel Standby button or SR 9 remote
control’s [ON] button.
IR CHANNEL
The C 368 has the capability to operate via Alternate IR channel. This is
useful if you have two NAD products that can be operated by similar
remote control commands. With alternate IR Channel, two dierent NAD
products can be controlled independently in the same zone by setting
each one to a dierent IR channel.
IR Channel Assignment
The C 368 and the SR 9 remote control must be set to the same channel.
To change the IR Channel on the C 368
While at IR Channel menu, use the [a/s] to select through Channel 0 to
Channel 3. Press [ENTER] to select preferred IR Channel setting. C 368 IR
Channel is defaulted to Channel 0.
To change the IR Channel on the SR 9 remote control
Include a channel number before the library code. For SR 9, library code
“10” is the default library table for AMP device. To select this AMP”
library table for Channel 0, retain the library code “10” (or “010”).
If you want to load the AMP library table on ”Channel 1” prex the
library code with “1” to indicate association with “Channel 1”. Load then
the AMP library table using the code “110”. Repeat the same for MP
(130) and TUNER (140).
OPERATION
USING THE C 368
IR Channel
SettingsSource Setup
Channel 0
Settings
Auto Sense
SettingsSource Setup
Off
Settings
Auto Standby
SettingsSource Setup
Normal Mode
Settings
14