Operation Manual

CONDITION POSSIBLE CAUSES POSSIBLE SOLUTIONS
No power. Mains power cord unplugged from mains
power source or from M22’s AC mains input.
Connect the mains power cord to M22’s AC mains
input and then plug into a mains power source.
Power switch is o. Switch ON the Power switch.
M22 at standby mode. Press o (Standby) button to switch ON the M22
from standby mode.
M22 always at standby mode; cannot
be switched ON using the o (Standby)
button.
A mono plug is plugged-in at the +12V
TRIGGER IN port of the rear panel.
Unplug the mono plug.
No sound. No input signal applied through the analog
audio input ports.
Check that there is active input signal applied
through the analog audio input ports.
External source volume control is set to
minimum level.
Turn up external sources volume control until
audio is heard.
No sound one channel. Speaker not properly connected or damaged. Check connections and speakers.
Input lead disconnected or damaged. Check leads and connections.
There is no BALANCED audio output. SELECT switch is set to SINGLE-ENDED. Set SELECT switch to BALANCED.
There is no SINGLE-ENDED audio output. SELECT switch is set to BALANCED. Set SELECT switch to SINGLE-ENDED.
REFERENCE
TROUBLESHOOTING
9