Use and Care Manual

Page 4
GENERAL DIRECTIVES AND REFERENCES
ELECTRICAL GROUNDING SPECIFICATIONS
The system’s power unit must absolutely be grounded. In the event of a malfunction or a power unit failure, the grounding
provides the path of least resistance to any electrical current, minimizing the risk of electric shock. The power unit’s power cord
has a length of 65’’ (1,65m) and is tted with a grounding wire and grounding pin. The power unit‘s power cord must always be
directly plugged into a suitable electrical outlet which is itself properly installed and properly grounded, in conformity with the
current local electrical standards.
Do not use an extension cord(s) to connect the power unit to the electrical outlet.
General guidelines to be respected at all time
1. The power unit must be installed in a well-ventilated area, protected from weathering and away from all sources of heat.
2. This central vacuum system is designed for dry surfaces and must not be used on wet surfaces or used in any circumstances to
pick up liquids or to clean wet carpets or any wet ground.
3. The filter cage must be covered at all times by the permanent filter during operation of the system.
4. The motor housing must never be obstructed in any way to prevent damaging or overheating.
5. Do not use this system to pick up mud or similar substances. To vacuum baking flour, talcum powder, cement or gypsum dust,
will have for effect to obstruct and clog the filter media; you have to clean the filter several times during and after such
pick-ups. Otherwise, the motor will overheat and may be damaged.
6. Do not attempt to shorten or modify the power cord in any way.
7. As a safety measure, unplug the power cord prior to proceed to maintenance or servicing.
8. In order for the warranty to remain valid, any repairs or servicing on the power unit must only be performed by an authorized
service center.
9. The power unit's position must be so that the power cord and electrical outlet are always easily accessible.
10. Pertaining to the use of an electrified valve (110 VAC) (intended for the connection of a current-carrying hose and electrically
motorized brush):
-Only connect a current-carrying hose to this wall valve
-Do not install a current-carrying valve outdoors
-Do not use a damaged hose, bring in the hose for repair at an authorized service center.
WARNING
Improper connection of the power unit grounding wire can
result in the risk of electric shock. If you are in doubt of a
proper grounding, contact a professional electrician. Do not
modify the power cord supplied with this power unit. If this
power cord connector does not fit your electrical outlet, have
the proper electrical outlet installed by a professional
electrician.
This power unit is designed to be used on a nominal electrical
circuit of 15 A. 110-120 VAC in 60 Hz. The power cord is fitted
with a grounding pin. Make sure that the power cord is
plugged into an electrical outlet having the same
specifications. This appliance should be used without an
adapter. We recommend to install this unit on its own
independent circuit and breaker, but not necessary to do so.
IMPORTANT
The manufacturer shall not be held responsible for damages
caused by the inappropriate use of this system. The warranty
does not cover the damages caused by improper use of this
system or the problems resulting from an installation that
does not meet the specifications or any structural or
functional alterations made to the power unit. An inappropri-
ate, not-recommended installation of the system or the
power unit made without respecting the directives of this
document will equally be considered as a misuse. All condi-
tions and restrictions are set forth in the limited warranty and
in the user manual. To optimize the performances and the
life of your Nadair power unit, it is important to do regular
maintenance and cleaning of the filter according to the
guidelines listed in this user manual..