User's Manual
ZDC ZA-5000 User's Manual V2.2.5 
Chapter 6 Troubleshooting 
Page 49
•  Wireless Channel/Frequency 
Try to change other channel 
•  Wireless disturbance 
Check whether there are other wireless equipments nearby AP; make sure they do not 
disturb AP. 
Q 5. The wireless becomes unstable such as ping timed out and lose packet after a period of 
well work? 
This situation may the wireless network is disturbed by something, what you can do is 
following steps: 
(1).  check whether every joint point of network is well(such as Ethernet port,antenna 
connection) 
(2).  Change the channel if the Link Test value is not high,excluding other wireless 
equipments disturb AP.   
(3).  Restart AP. 
(4).  Default AP and restore last settings. 
(5).  Please call the sales if can not solve problem after all. 
Q 6. How to adjust output power? 
In the Wireless Settings page, you can do it. 
Diagram 9 Output Power   
  Full  1/2  1/4  1/8  Min 
Output Power  18dbm  15dbm  12dbm  9dbm  6dbm 
Q 7. Why the buzzer stops work after a period of time, and how to close buzzer manually? 
As design the buzzer will automatically stop ringing after working one hour. 
You can choose buzzer switch to OFF to close buzzer in WDS Settings page.   
Q 8. Why can not open WEB page of remote wireless bridge in local network? 
Because this kind of settings will slow the response of remote AP WEB Server, just waiting 
for several minutes or restarting remote wireless bridge is a way to solve problem. We 
suggest you set AP in local wired Ethernet network. 
Fixed power level.