User's Manual

20
WI1024J 2WAY-UNIVKF Installation Instructions
Universal Operation
Wiring for Stay Mode
When installed on a control panel which provides “Automatic Interior Bypass”, the system can be armed in either the AWAY or
STAY mode through the KeyFob. A system which provides “Automatic Interior Bypass” controls the Interior protection by
automatically bypassing the Interior Zones if the system is armed and the exit/entry door is not opened. Program the control panel
for “Automatic Interior Bypass”, or for “Home Away with Delay” (for the NAPCO Express Series Stay mode). Each time the system
is armed by a press of KeyFob button [
ON/OFF
], the system will arm in the AWAY mode, providing complete protection. If the
KeyFob button [ON/OFF] is held down for 2 seconds, the system will arm in the in the STAY mode, providing perimeter protection
only.
Choose the appropriate wiring scheme for your control panel.
When KeyFob button [
ON/OFF
] is pressed, the PGM terminal of the receiver will cause a violation of the exit entry zone,
which will arm the system in the AWAY mode.
If KeyFob button [
ON/OFF
] is held down for 2 seconds, the system will arm without the PGM violation of the E/E zone, which
will arm the system in the STAY mode.
For the NAPCO Express Series
and GEM-P400/P800 controls:
Program the interior zones for
for home away with delay and
wire as shown.
Install jumper J2 to invert
PGM operation
Zone programmed
for Exit Entry
Typical STAY mode wiring for a control
panel using End of Line resistors
Protective zone
device and EOLR
PGM
5
6 7
+ -
EOLR
Typical STAY mode wiring for a control
panel using Zone Doubling
Zone programmed
for Exit Entry
Protective zone device and
Zone Doubling Resistor.
PGM
5
6 7
+ -
ZDR
Wiring for Stay Mode
Install Jumper
across Config
Pins J2
J2
EOLR PANEL
ZONE DOUBLED PANEL
2WAY-UNIVKF_WI1024J.19_I...
page 20
Friday, February 13, 2004 08:57
Composite