The system can be installed out of the box without any configuration changes. First ensure the alarm control panel is wired
and working with a standard wired keypad as KP ADDR #1 before you continue
. Be sure to use the same "type" of keypad
(either "Classic" or "K Series" Stay/Away) that you plan to configure the system to use. Do not wire the IBR-ZREMOTE yet.
STEP 1: PREPARE THE IBR-ITAB
The IBR-ITAB has an internal battery that may need recharging. Press and hold the "Back/Power" button
(shown at right) until the display starts to turn on (then release the button). After the IBR-ITAB tablet starts,
observe the battery indicator icon (upper right); if green or yellow, the battery has enough charge to complete
the installation. Press and hold the "Back/Power" button again until the power off message appears and
turn off the tablet. If the battery indicator icon is red, you can install and mount the charging plate as
described in WI1944 or just connect the power adapter to the charger plate (observing polarity) and power
the IBR-ITAB to continue.
STEP 2: CONFIGURE THE CONTROL PANEL
The alarm control panel must have the correct firmware version installed to utilize all features of the IBR-ZREMOTE.
Required are:
PCD-Windows Quickloader: V6.12 or greater (located on the enclosed IBR-ZREMOTE support CD)
Control panels GEM-X255, GEM-P9600 and GEM-P3200: Firmware version 60A22-4 or greater (included in
IBR-ZREMOTE box)
Control panels GEM-1664, GEM-P1632 and GEM-P816: Firmware version 30R-9 or greater (included in IBR-
ZREMOTE box)
Note: The following version control panels may be upgraded for iBridge compatibility:
GEM-P3200 and P9600 controls running firmware version 20 or greater, released in May of 1999.
GEM-P816, P1632 and P1664 controls running firmware version 30 or greater, released in August of 1999 (V10
can be used if a 32 pin socket is available on the control panel motherboard).
Perform the following:
2A. If installing the IBR-ZREMOTE on a previously programmed control panel, launch Quickloader 6.12 and upload the
control panel program configuration to an account on your PC. In all cases ensure a conventional keypad is
connected at keypad address 1 for steps that follow.
Back / Power
Button