Home Security System User Manual

X GEM-P1664 Installation Instructions
L NAPCO Security Systems
WI1424A 1/06
Page 26
KEYPAD MESSAGES
The GEM-RP1CAe2/GEM-K1CA Keypads can display the below messages. The GEM-RP2ASe2/GEM-K2AS will display similar
abbreviated messages that may scroll through two screens. Note: See page 7 for a listing of the keypad specific User Guides avail-
able. These User Guides contain more details regarding the various keypad messages.
SYSTEM READY - All zones operating; system can be armed. 1
through 4 = Area.
ARMING YYY/XXX SECONDS - Exit delay in progress. XXX = exit
time remaining in 10-second decrements; YYY = AWAY or
STAY. Arming then becomes ARMED.
DISARM NOW/XXX SECONDS - Entry delay in progress. XXX =
entry time remaining in 10-second decrements.
SYSTEM ARMED - Panel armed. GEM-RP1CAe2/GEM-K1CA
keypads only.
ZONE FAULTED - One or more zones not secured. Display status
for zone description(s). GEM-RP1CAe2/GEM-K1CA only.
CAN'T ARM SYSTEM/ZONE FAULTED - Arming attempted with
Priority Zone in trouble. Secure zone to arm.
DAY ZONE TROUBLE - Trouble condition on Day Zone, followed
by one or more zone descriptions.
INVALID ENTRY/TRY AGAIN - Wrong code/time/area number
entered.
CAN'T ARM SYSTEM/PRESS RESET KEY - Arming attempted
with System Trouble present. Press the
C button and then
arm the system.
ALARM - Alarm condition, followed by one or more zone
descriptions.
FIRE ALARM - Alarm condition on a Fire Zone. Enter your code
then press the
U or D button to silence the sounder. Correct
the cause of the alarm, then press the
C button again. Fire
alarm condition, followed by one or more zone descriptions.
SYSTEM TROUBLE - A System Trouble display will be followed by
one or more of the following error codes:
AC POWER FAIL/E01-00 SERVICE. Power failure. Check
power transformer. Check for blown fuse or circuit breaker;
general power outage.
LOW BATTERY/E02-00 SERVICE. Battery below 11 volts. If
not recharged within 24 hours, replace it.
COMM FAIL/E03-00 SERVICE. Unsuccessful communication
to central station. Note: Will also display if panel improperly
programmed to report; i.e., Report Alarm, Report Codes,
Subscriber ID Numbers, etc. must be programmed.
WIRELESS TROUBLE/04-NN SERVICE. Wireless transmitter
supervisory failure. NN = transmitter number.
WIRELESS LOWBATT/E05-NN SERVICE. Rf transmitter low
battery. NN = transmitter number.
SYSTEM TROUBLE/E06-NN SERVICE. Rf receiver response
trouble. NN = receiver number.
SYSTEM TROUBLE/E07-00 SERVICE. Download failure.
SYSTEM TROUBLE/E08-00 SERVICE. Telephone line failure
(system trouble displays after a fixed 60 second delay).
SYSTEM TROUBLE/E09-00 SERVICE, NO PANEL PROGRAM.
System cold start not programmed after address 2286.
SYSTEM TROUBLE/E10-NN SERVICE. Keypad response
failure. NN = keypad number.
SYSTEM TROUBLE/E11-NN SERVICE. Keypad tamper cover
removed. NN = keypad number.
SYSTEM TROUBLE/E12-NN SERVICE. Expansion zone
module failure. NN = module number.
SYSTEM TROUBLE/E13-NN SERVICE. EZM module cover
removed. NN = module number.
SYSTEM TROUBLE/E14-NN SERVICE. Relay board response
failure. NN = relay board number.
SYSTEM TROUBLE/E15-NN SERVICE. Wireless transmitter
tamper cover removed. NN = transmitter number.
SYSTEM TROUBLE/E16-NN SERVICE. Receiver jammed. NN
= receiver number.
SYSTEM TROUBLE/E17-NN SERVICE. Receiver cover
removed. NN = receiver number.
SYSTEM TROUBLE/E18-NN SERVICE. Key fob RF transmitter
low battery. NN = key fob transmitter number.
SYSTEM TROUBLE/E19-00 SERVICE. Internal user memory
error. Select RESET SYSTEM TBL. Press the
U or D
button, then the
C button.
SYSTEM TROUBLE/E20-00 SERVICE. Internal dealer memory
error.
SYSTEM TROUBLE/E22-NN SERVICE. No trip detected on PIR
Supervision Zone within programmed Sensor-Watch time.
NN = Zone number. To reset, press NEXT/YES button at
RESET SENSOR MSG” function display.
SYSTEM TROUBLE/E27-00 SERVICE. Printer Failure. Call
installing company for service.
SYSTEM TROUBLE/E39-00 SERVICE. Receiver capacity error.
SYSTEM TROUBLE/E40-00 SERVICE. RF Self-Test failure.
SYSTEM TROUBLE/E41-NN SERVICE. Trouble condition on a
Fire Zone. Press
C button to silence the sounder.
Correct the trouble, then press the
C button again.
SYSTEM TROUBLE/E51-00 SERVICE - Alarm Output
Supervisory.
SYSTEM TROUBLE/E99-00 SERVICE. Keypad Panic shorted
too long (RP2/K2 and RP3/K3 keypads).
NN OUT OF SYSTEM - Keypad inoperative. NN = keypad
number.
FAULT FIND/RF SIGNAL POWER - Fault-find Mode activated.
Keypad Messages