Home Security System User Manual

L NAPCO Security Systems
X GEM-P1664 Installation Instructions
WI1424A 1/06
Page 45
Glossary
255 is entered the system will display 000 to request a re-entry. Note: Only the panel zones’ integration times are programmable. EZM’s
will continue to use either 50 or 750 ms as selected by jumpers on the EZM. In addition, zone responses are enabled only when armed.
Selectable loop-response times for Zones 1–8 are:
750mS (.75 sec.): The slowest loop-response time, recommended for use with magnetic contacts, window foil, etc. Unless
programmed otherwise, loop-response time will be 750mS for all zones.
50mS (.05 sec.): Used for momentary Panic Buttons and area-protection devices, such as photoelectric eyes, passive infrared
sensors, floor mats, etc.
Zone Status
In high security installations where Disable Auto Status has been programmed, enter the User code and press
A or R until
"Display Zone Status Y/N" is displayed. Press NEXT/YES and then NEXT/PRIOR to scroll through any faulted zones.
Zone Type See Central Station Receiver Data Formats: Modem Formats
2-Wire, 4-Wire Smoke Detectors See Smoke Detectors
24-Hour Zone
A zone selected for "24-Hour Zone" that provides protection at all times, whether or not the system is armed. If "Alarm Output",
"Pulsed Alarm Output", "PGM1 Output", "PGM2 Output" and "Keypad Sounder on Alarm" are not selected, then the zone is
programmed for silent alarm. In this case, there will be no indication on the keypad if the zone is tripped. A 24-Hour Zone will be
reset when the zone fault has been cleared and the area has been armed and disarmed. Note: Do not program a Day Zone as a
24-Hour Zone.
24 Hour Day Zone Trouble--Normally used for a hidden N/C panic button that when pressed, trips an alarm. Switch open = alarm.
Short or cut in the loop = trouble.