Technical Manual

Napco iSecure Security System All technical manuals are available in PDF format at tech.napcosecurity.com 5
Open the box and locate OI404LF, a card that specifies the
system Radio ID number, Network MAC address and Master
Code. Keep this card handy during the installation pro-
cess, but always store in a secure location.
Account and Central Station Activation
1. Visit (www.NapcoComNet.com)
2. Enter your iSecure ID # and the select your service plan
3. Access the iSecure Cloud Web Portal at
www.iSecureByNapco.com. Click Dealer Login. Refer to
the OI404LF card and enter your Dealer User ID, Pass-
word and Radio ID ("iSecure LTE ID#"). Click Submit.
4. Click General Settings and in the Master Security Code
field, enter the Master Code (also refer to the OI404LF
card).
(Optional) Enter a Download Security Code and a
Dealer Keypad Programming Code in the fields pro-
vided.
5. Click Save. Any changes to the Master Security Code
require that you exit and re-enter the iSecure Cloud Web
Portal. Therefore, quit your browser and log back in.
6. Click Central Station Reporting and enter your central
station account and telephone number. Click Save.
7. Download the Kit configuration into your Go-Anywhere
Hub: Click Upload/Download > Full Download and
click Yes to confirm. While waiting for the download to
complete, the yellow "IP Network Wi-Fi" LED will be on
steady during the download process and the Hub will
beep when the download is complete.
After you have downloaded the Kit configuration into your Go-
Anywhere Hub, you can add and easily configure any addi-
tional devices as detailed further in this manual (see the Table
of Contents for the device you wish to add).
Hardware Installation Instructions
1. Open box and remove all components from the Kit and
place on a clean table top. Be sure that OI404LF (the
card that specifies the system Radio ID, Master Code,
etc.), is in a secure location.
2. Power all battery-powered devices, either by inserting
batteries or by removing battery ribbons/fishpaper. With
the Kit 1 keypad (ISEC-WL-KEYPAD), insert battery
(provided) into 1 of the 2 battery holders. Place magnets
next to ISEC-DW-XMITTERs to make them appear to
the system as "closed" (see page 18 for where to locate
the magnet).
3. Separate the Go-Anywhere Hub housing: With a flat
head screwdriver, push in the two tabs at the bottom to
unhook, then carefully separate the two parts of the
housing.
4. Place a 12V, 4AH (or 5AH) battery (not supplied) into its
bracket, terminals facing the rear of the unit. Secure us-
ing the Velcro strip. Connect flying leads to battery termi-
nals "red to red" and "black to black".
5. Re-join the front and rear Go-Anywhere Hub housing,
thus powering the unit. Verify that the bottom right green
LED on the Hub flashes for about 10 seconds.
6. Wire the supplied 16VAC transformer wires: Remove the
wiring cover on the back of the Hub and connect each
wire to each of the bottom two screw terminals. Note:
The transformer is a required part of a working system.
7. Wait at least 30 seconds until the "Cellular Signal
Strength" green LED (right side, second from top) flashes
a signal strength of 3 or higher.
8. Confirm keypad operation by arming and disarming the
system (use the default User Code 1 2 3).
9. With the system disarmed, test each transmitter (one at a
time) by removing and replacing its magnet.
10. Test the PIR by facing it towards a wall, or upside down
so that no motion is detected for at least 5 minutes. En-
sure the keypad displays a faulted zone when the PIR is
triggered by pointing the PIR towards the tester.
11. If additional wireless devices were added to the system
(programmed using the iSecure Cloud Web Portal and
downloaded to the Hub) ensure the devices are similarly
tested.
12. After confirming operation of all parts of the system,
physically install each device in their desired location as
detailed in this manual (see the Table of Contents for
each device).
13. Determine the installation location noise level: After in-
stalling the Go-Anywhere Hub in its final location, remove
power (unplug AC and open the Hub enclosure to mo-
mentarily disconnect the battery), wait 10 seconds, then
snap the Hub enclosure back together and plug the Hub
transformer into a wall outlet. This momentary removal
of power will allow the Go-Anywhere Hub to determine
the relative wireless noise level of each device at each of
their selected installation locations. IMPORTANT: All
wireless devices, including Z-Wave devices, must be sig-
nal tested with all enclosure covers fully closed, including
the Go-Anywhere Hub.
Now install and launch the iBridge smartphone app to con-
firm the signal strength of each transmitter:
iOS / Android Phone App Installation
Purchase and install the free smartphone app (search for
"iBridge" in your online app store)
Launch the app and tap System (the "gears" icon)
Tap Configure Remote Logins > New User
In the Username field, enter the Radio ID ("iSecure LTE
ID#") located on the card (OI404LF)
In the Password field, enter the default Password 1 2 3 4
Type a Display Name
Tap Log In (when connected, the bottom right will indicate
"Connected..."
Tap Security
Enter the Master Code located on the card (OI404LF),
then tap MENU, BYPASS, (tap Next/Yes to DISPLAY RF
XMITTER STAT Y/N).
Tap Next/Yes to scroll forward through each zone (or tap
Prior/No to scroll through the previous zones). Signal
strength should be at least 3; we recommend 4 or greater)
New User Pre-Installation and Configuration Steps