Cold Start, Test and Reset Processes
Your iSecure Go-Anywhere Smart Hub and 900 MHz Keypads, Siren and take Over module can be reset back to their original
"default" conditions, i.e. the state each was in when they first left the factory. Proceed as follows:
Cold Start the Go-Anywhere Hub (Factory Default)
The Go-Anywhere Smart Hub can be reset back to its original "default" condition, clearing all programming and settings, includ-
ing all zones and keypads, and re-loading its factory default program.
1. Remove AC power from the Go-Anywhere Hub.
2. Separate the Go-Anywhere Hub front and rear housing by pushing in the two tabs at the bottom with a flat head screwdriv-
er until the tabs unhook. Battery power is removed upon separation of the housing.
3. Add a jumper to the two (2) pins of JP2 (located at the top left of the PC board).
4. Wait 60 seconds, or until error code E09-00 appears on the keypad or touchpad display.
5. Remove jumper from JP2.
6. Reassemble the front and rear housing and re-connect AC power.
7. Perform a Full Download of the Hub programming.
Factory Reset the ISEC-WL-SIREN
1. Remove power.
2. Place jumper on J1.
3. Power up siren. The siren will blink once with a strobe flash.
4. Remove jumper J1.
If the default process is successful, upon power up the LED will blink three times.
If unsuccessful, the LED will blink only once.
Test the ISEC-WL-SIREN (Strobe/Sounder Test)
Use hearing protection before testing! The siren is rated at 85dBA.
1. Remove AC and batteries.
The jumper pins on the siren PCB are marked "2 1" (see image at right). With the
unit oriented with the wall outlet AC prongs at the top, the factory storage position
for the jumper is across the top two pins.
2. Place jumper across the two bottom pins as shown to begin the test process.
3. Install batteries, observing polarity.
Upon the insertion of the 4th battery, the siren will sound and the strobe will flash.
4. Remove jumper and store in the top two pins for future use.
5. Remove batteries to silence; replace batteries and restore AC (if necessary).
Factory Reset the ISEC-WL-MODULE Takeover Module
1. Remove power.
2. Place jumper on J1.
3. Power up the module.
4. Wait 10 seconds and remove jumper from J1.
If the default process is successful, upon power up the LED will slowly blink.
Factory Reset the ISEC-WL-KEYPAD Wireless Battery-Powered Standard Keypad
1. Press and hold the AREA ( ) button until "LF" appears in the display.
2. Press 0, 2, ENTER.
If the default process is successful, the "dot" in the left bottom corner of the display and the word READY will appear. If
unsuccessful, only the "dot" in the left bottom corner of the display will appear. Note: This reset proce-
dure can only be initiated either within 1 minute after power up, or when the keypad flashes "o#" (where #
is the keypad address).
Factory Reset the ISEC-WL-TOUCH Wireless 4.3" Full Color Security Touchscreen Keypad
1. From the Home screen, press the System Settings ("gears") icon (shown at right).
2. Enter the Master Security Code (refer to the OI404LF card), then press ENTER.
3. In the System Settings screen that opens, press the Dealer KP Config button.
4. Press the LearnOff button. The LearnStatus will change from ON to OFF.
5. Press Exit twice to save and exit.
Note: To verify the LearnStatus, re-enter the System Settings screen and press the Dealer KP Config button.
System Settings
("gears") icon
ISEC-WL-SIREN Strobe / Sounder
Test Jumper Pins
(jumper shown when starting test)
2 1
AC
prongs
(Store)
(Test)