User's Manual

21
W415-0447 / B / 05.24.05
FIGURE 48
1. Unplug the cord from the junction box
2. Pull the the tab on the receiver lock forward.
3. Pull up on the receiver and disconnect the wires.
4. Install the new receiver (see schematic Pg.23).
1. Remove the
hearth strip.
2. Open the right
control door.
3. Remove the
switch plate by pull-
ing on the left side.
4. Remove the valve
housing by pulling on
the handle.
5. Lift up and set the
housing towards the
back of the fire
place.
REMOTE RECEIVER REMOVAL
REMOTE AND VALVE ACCESS
The valve on the Madison is piped with two flex connectors
(one inlet, one outlet).
It can be removed or pulled forward for service.
1. Remove the wing nut and pivot the valve out from the slot
at the bottom of the valve.
2. Slowly pull the valve through the control door careful not
to kink the gas lines or wires.
VALVE REMOVAL
FIGURE 46
FIGURE 47
The control area can be accessed either through the control
door or through the access door inside the firebox.
Follow the door removal instructions. Remove the right side
panel. Remove the four screws from the access door.
Note: A new gasket will be required, when re-installing
the door (see replacement parts).
CONTROL DOOR
INNER ACCESS DOOR