Minimum clearance to combustible construction
from replace and vent surfaces:
f 

  
21
3
/

  
  
1
/
inches



     -

 Maximum input is 26,000 BTU/hr for both natural

-

high altitude input rating shall be reduced at the rate of 4%
for each additional 1,000ft. Maximum output for natural gas


pressure is 4.5 inches water column for natural gas and 11
inches water column for propane. Maximum inlet gas pressure
is 7 inches water column for natural gas and 13 inches water

is 3.5 inches water column for natural gas and 10 inches water
column for propane.

sitting room installations and is suitable for mobile home
installation. The natural gas model can only be installed in
a mobile home that is permanently positioned on its site and
fueled with natural gas.










  


FIGURE 1
-
 to conform with local
codes. Installation practices vary from region to region and it

for example: in Massachusetts State:
 

gas log.
A carbon monoxide detector is required in all rooms containing

The appliance off valve must be a “T” handle gas cock.
 
The appliance is not approved for installation in a bedroom or
bathroom unless the unit is a direct vent sealed combustion
product.
WARNING: This product must be installed by a licensed

commonwealth of Massachusetts.
In absence of local codes, install to the current CAN/CGA
-B149 Installation Code in Canada or to the National Fuel
Gas Code, ANSI Z223.1, and NFPA 54 in the United States.
Suitable for mobile home installation if installed in accordance
with the current standard CAN/CSA Z240MH Series, for gas
equipped mobile homes, in Canada or ANSI Z223.1 and NFPA
54 in the United States.
-
nected from the gas supply piping system during any pressure
testing of that system at test pressures in excess of 1/2 psig

piping system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping system
at test pressures equal to or less than 1/2 psig (3.5 kPa).



the full width and depth.
The optional heat circulating blower is supplied with a cord. If
installed, the junction box must be electrically connected and
grounded in accordance with local codes. In the absence of
local codes, use the current CSA C22.1 CANADIAN ELEC-
TRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL
ELECTRICAL CODE in the United States.








