User Guide

BUILT-IN UNIT INSTRUCTION GUIDE
N415-0107 / APR 28/06
Please use this manual in conjuction with your main manual to properly assemble your built-in grill. Refer to the
main manual for operating, cleaning, and maintenance instructions. This grill is designed for non-combustible
enclosures only, and must be installed and serviced by a qualified installer to local codes.
BUILT IN PROPANE GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and piping should be located as
shown in the built-in instructions. Do not use hose to connect the unit. It must be connected with either rigid pipe, copper tube or an
approved flexible metal connector. The installation must comply with CAN B149.1 Natural Gas and Propane installation code in
Canada, or to the National Fuel Gas code, ANSI Z223.1 in the United States. The minimum recommended piping size is NPS 1/2"
for rigid pipe, and 1/2" OD for copper tubing (based on a 20 ft run). Longer runs may require larger sizes to conform with CAN
B149.1. Propane Gas Installation Code in Canada or to the National Fuel Gas Code, ANSI Z223.1 in the United States. The gas
supply must be connected to the 3/8” flare elbow fitting located under the right hand side of the control panel. If installing a side
burner, a separate line must be branched off to the side burner unit and enter the side burner opening at the specified location. If the
enclosure is to house a propane cylinder, the tank portion of the enclosure must be ventilated according to local codes, and must not
have communication with the cavity used to enclose the gas grill. The tank can not be stored below the gas grill.
BUILT IN NATURAL GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and piping should be located as
shown in the built-in instructions. Do not use hose to connect the unit. It must be connected with either rigid pipe, copper tube or an
approved flexible metal connector. The installation must comply with CAN B149.1 Natural Gas and Propane Installation Code in
Canada, or to the National Fuel Gas Code, ANSI Z223.1 in the United States. The minimum recommended piping size is NPS 1/2"
for rigid pipe, and 5/8" OD for copper tubing (based on a 20 ft run). Longer runs may require larger sizes to conform with CAN
B149.1. Natural Gas Installation Code in Canada or to the National Fuel Gas Code, ANSI Z223.1 in the United States.
Built in units are supplied with a drip pan which holds only a minimal amount of grease. To prevent grease fires, the pan must
be cleaned after each use.
SERIAL #______________________

Summary of content (9 pages)