Installation Manual
Table Of Contents
- W415-1285_Fe
- 1.0 installation overview
- 2.0 introduction
- 3.0 venting
- 4.0 installation
- 5.0 framing
- 6.0 Finishing
- 6.1 main SAFETY SCREEN removal / installation
- 6.2 end SAFETY SCREEN removal / installation (bhd4p only)
- 6.3 MAIN door removal / installation
- 6.4 END DOOR REMOVAL / installation (bhd4p only)
- 6.5 control panel removal
- 6.6 hearth pad installation
- 6.7 log placement
- 6.8 glass media installation
- 6.9 logo placement
- 7.0 wiring diagram
- 8.0 operating instructions
- 9.0 Adjustment
- 10.0 MAINTENANCE
- 11.0 replacements
- 12.0 accessories
- 13.0 troubleshooting
- 14.0 warranty
- 15.0 SERVICE HISTORY
- W415-1285_Ff
- 1.0 vue d'ensemble de l'installation
- 2.0 introduction
- 3.0 éVACUATION
- 3.1 LONGUEURS DES CONDUITS D’ÉVACUATION ET COMPOSANTS
- 3.2 INSTALLATIONS TYPIQUES D'ÉVENTS
- 3.3 INSTALLATIONS PARTICULIÈRES D'ÉVENTS
- 3.4 convertir l'Évacuation de 5/8" À 4/7"
- 3.5 EMPLACEMENTS ET DÉGAGEMENTS MINIMAUX DE LA TERMINAISON
- 3.6 CHARTE D'APPLICATION DES ÉVACUATIONS
- 3.7 LÉGENDE
- 3.8 VALEURS DU COUDE EN LONGUEURS D'ÉVENT
- 3.9 TERMINAISON HORIZONTALE
- 3.10 TERMINAISON VERTICALE
- 4.0 installation
- 5.0 ossature
- 6.0 Finitions
- 6.1 RETRAIT de l'écran de protection PRINCIPAL et l'installation
- 6.2 RETRAIT de l'écran de protection fin et l'installation (SEULEMENT bhd4p)
- 6.3 installation / enlèvement de la porte PRINCIPALE
- 6.4 Enlèvement DE LA PORTE D'EXTRÉMITÉ / INSTALLATION (SEULEMENT bhd4p)
- 6.5 enlèvement de PANNEAU DE CONTRÔLE
- 6.6 INSTALLATION des bases de protection (bHD4ST Et bHD4P SEULEMENT)
- 6.7 DISPOSITION DES BÛCHES
- 6.8 installation des BRAISES VITRIFIÉES
- 6.9 mise en place du logo
- 7.0 branchement électrique
- 8.0 instructions de fonctionnement
- 9.0 réglages
- 10.0 Entretien
- 11.0 rechanges
- 12.0 accessOires
- 13.0 dépannage
- 14.0 garantie
29
W415-1285 / F / 12.21.16
EN
IMPORTANT: This appliance requires a minimum inside enclosure height of 50" (127cm), measured from the
bottom of the appliance. For temperature requirements, this area must be left unobstructed.
NOTE: THIS APPLIANCE IS NOT LOAD BEARING.
IMPORTANT: The firestop assembly provided must be used when the vent pipes pass through any
walls or are terminated horizontally.
If reduced to 4/7" venting, a new firestop is required (W010-3440).
COMBUSTIBLE
NON-COMBUSTIBLE
BRICK
3" [76mm]
2"
[51mm]
FIRESTOP
43"
[109.2cm]
MINIMUM
RISE **
45" [114.3cm]
6" [152mm]
MINIMUM WALL
38 1/4"
[97.2cm]
SAFETY BARRIER
3" [76mm] *
62 1/4"
[158cm]
MINIMUM
TO CEILING
11 3/4"
[298mm]
50"
[127cm]
MINIMUM
ENCLOSURE
COMBUSTIBLE
NON-COMBUSTIBLE
BRICK
3" [76mm]
2"
[51mm]
FIRESTOP
43"
[109.2cm]
MINIMUM
RISE **
43 1/4" [110cm]
38 1/4"
[97.2cm]
SAFETY BARRIER
3" [76mm] *
62 1/4"
[158cm]
MINIMUM
TO CEILING
11 3/4"
[298mm]
50"
[127cm]
MINIMUM
ENCLOSURE
5.2 MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES
5.2.1 SEE-THRU (BHD4ST)
5.2.2 PENINSULA (BHD4P)
* Within the appliance enclosure a minimum 3” (76mm) clearance between the top of the vent pipe and
combustible materials is required. All other clearances within the enclosure, including where the vent pipe exits
the enclosure are subject to 2” (51mm) to the sides and bottom and 3” (76mm) to the top for horizontal and 2”
(51mm) for vertical.
** See "VENTING" section.
COMBUSTIBLE
NON-COMBUSTIBLE
BRICK
3" [76mm]
2"
[51mm]
FIRESTOP
43"
[109.2cm]
MINIMUM
RISE **
45" [114.3cm]
6" [152mm]
MINIMUM WALL
38 1/4"
[97.2cm]
SAFETY BARRIER
3" [76mm] *
62 1/4"
[158cm]
MINIMUM
TO CEILING
11 3/4"
[298mm]
50"
[127cm]
MINIMUM
ENCLOSURE
COMBUSTIBLE
NON-COMBUSTIBLE
BRICK
3" [76mm]
2"
[51mm]
FIRESTOP
43"
[109.2cm]
MINIMUM
RISE **
43 1/4" [110cm]
38 1/4"
[97.2cm]
SAFETY BARRIER
3" [76mm] *
62 1/4"
[158cm]
MINIMUM
TO CEILING
11 3/4"
[298mm]
50"
[127cm]
MINIMUM
ENCLOSURE