Installation Manual
Table Of Contents
- W415-1285_Fe
- 1.0 installation overview
- 2.0 introduction
- 3.0 venting
- 4.0 installation
- 5.0 framing
- 6.0 Finishing
- 6.1 main SAFETY SCREEN removal / installation
- 6.2 end SAFETY SCREEN removal / installation (bhd4p only)
- 6.3 MAIN door removal / installation
- 6.4 END DOOR REMOVAL / installation (bhd4p only)
- 6.5 control panel removal
- 6.6 hearth pad installation
- 6.7 log placement
- 6.8 glass media installation
- 6.9 logo placement
- 7.0 wiring diagram
- 8.0 operating instructions
- 9.0 Adjustment
- 10.0 MAINTENANCE
- 11.0 replacements
- 12.0 accessories
- 13.0 troubleshooting
- 14.0 warranty
- 15.0 SERVICE HISTORY
- W415-1285_Ff
- 1.0 vue d'ensemble de l'installation
- 2.0 introduction
- 3.0 éVACUATION
- 3.1 LONGUEURS DES CONDUITS D’ÉVACUATION ET COMPOSANTS
- 3.2 INSTALLATIONS TYPIQUES D'ÉVENTS
- 3.3 INSTALLATIONS PARTICULIÈRES D'ÉVENTS
- 3.4 convertir l'Évacuation de 5/8" À 4/7"
- 3.5 EMPLACEMENTS ET DÉGAGEMENTS MINIMAUX DE LA TERMINAISON
- 3.6 CHARTE D'APPLICATION DES ÉVACUATIONS
- 3.7 LÉGENDE
- 3.8 VALEURS DU COUDE EN LONGUEURS D'ÉVENT
- 3.9 TERMINAISON HORIZONTALE
- 3.10 TERMINAISON VERTICALE
- 4.0 installation
- 5.0 ossature
- 6.0 Finitions
- 6.1 RETRAIT de l'écran de protection PRINCIPAL et l'installation
- 6.2 RETRAIT de l'écran de protection fin et l'installation (SEULEMENT bhd4p)
- 6.3 installation / enlèvement de la porte PRINCIPALE
- 6.4 Enlèvement DE LA PORTE D'EXTRÉMITÉ / INSTALLATION (SEULEMENT bhd4p)
- 6.5 enlèvement de PANNEAU DE CONTRÔLE
- 6.6 INSTALLATION des bases de protection (bHD4ST Et bHD4P SEULEMENT)
- 6.7 DISPOSITION DES BÛCHES
- 6.8 installation des BRAISES VITRIFIÉES
- 6.9 mise en place du logo
- 7.0 branchement électrique
- 8.0 instructions de fonctionnement
- 9.0 réglages
- 10.0 Entretien
- 11.0 rechanges
- 12.0 accessOires
- 13.0 dépannage
- 14.0 garantie
33
W415-1285 / F / 12.21.16
EN
APPLIANCE
RECESS OR
ALCOVE
AREA
NOTE: Recesses or alcoves above the appliance can be made as deep as desired provided the minimum
clearances to combustibles are maintained.
Non-combustible material can be used, provided the minimum clearances to combustible materials are applied.
The minimum enclosure volume must be increased by no less than the volume of the recess. This adjustment
can be made by increasing any or all of the height, width and depth of the enclosure.
71.2
ENCLOSURE
AREA
5.5 ALCOVE ENCLOSURE
Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the
clearance needed.
!
WARNING
RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE
TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO
OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE
CLEARLY MAINTAINED.
WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE
HEAT RESISTANT TO PREVENT DISCOLOURATION.
73.1
MANTEL DIMENSIONS
Ref Height Depth
D
4" (102mm) 2” (51mm)
C
6" (152mm) 4” (102mm)
B
8" (203mm) 6” (152mm)
A
10" (254mm) 8” (203mm)
LA
TABLETTE
HAUTEUR
DE
PROFONDEUR DE
LA TABLETTE
Ref Mantel Height Mantel Depth
A
B
C
D
E
16” (406.4mm)
14” (355.6mm)
12” (304.8mm)
10” (254mm)
8” (203.2mm)
6” (152.4mm)
F
0” (0mm)
2” (50.8mm)
4” (101.6mm)
6” (152.4mm)
8” (203.2mm)
10” (254mm)
Ref
G
H
I
J
K
L
MANTEL
HEIGHT
MANTEL DEPTH
12
10
8
6
4
2
1
3
4 5 6 7 8 9 10
Ref Hauteur Plafondeur
A
B
C
D
E
16” (406,4mm)
14” (355,6mm)
12” (304,8mm)
10” (254mm)
8” (203,2mm)
6” (152,4mm)
F
0” (0mm)
2” (50,8mm)
4” (101,6mm)
6” (152,4mm)
8” (203,2mm)
10” (254mm)
Ref
G
H
I
J
K
L
A
B
C
D
E
F
G H I J K L
( " )
( " )
A
B
C
D
38 1/4"
(97.2cm)
TOP OF
APPLIANCE
5.6 MINIMUM MANTEL CLEARANCES










