manual
25
EN
www.napoleongrills.comN415-0424 MAR 08.18
Leak Tes ng Instruc ons
WARNING! A leak test must be performed annually and each me a cylinder is hooked up or if a
part of the gas system is replaced.
WARNING! Never use an open ame to check for gas leaks. Be certain no sparks or open ames
are in the area while you check for leaks. Sparks or open ames will result in a re or explosion,
damage to property, serious bodily injury, or death.
Leak tes ng: This must be done before ini al use, annually, and whenever any gas components are
replaced or serviced. Do not smoke while performing this test, and remove all sources of igni on. See Leak
Tes ng Diagram for areas to check. Turn all burner controls to the o posi on. Turn gas supply valve on.
Brush a half-and-half solu on of liquid soap and water onto all joints and connec ons of the regulator,
hose, manifolds and valves.
Bubbles will indicate a gas leak. Either ghten the loose joint or have the part replaced with one
recommended by the Napoleon Customer Solu ons department and have the grill inspected by a cer ed
gas installer.
If the leak cannot be stopped, immediately shut o the gas supply, disconnect it, and have the grill
inspected by a cer ed gas installer or dealer. Do not use the grill un l the leak has been corrected.
STOP
X