W415-1140 / 11.07.12
Due to the many different nish materials used on walls, it is highly recommended that you consult your local
builder before you install this appliance in the wall.
Select a location that is not prone to moisture and is located at least 36" away from combustible materials such
as curtain drapes, furniture, bedding, paper etc.
3.3 RECESSING INSTALLATION
A. Once the rough opening has been prepared, and the power has been routed to the right side of the
recess, the appliance may be installed.
B. Lift the appliance up to the opening.
C. The hardwiring and electrical connection must be made prior to sliding the appliance into place.
D. Level the appliance and secure it to the wall using the brackets provided, refer to the "MOUNTING
BRACKET INSTALLATION" section.
* NOTE: In order to avoid the possibility of exposed insulation or vapour barrier coming in contact
with the appliance body, it is recommended that the walls of the appliance enclosure be " nished"
(i.e. drywall/sheetrock), as you would nish any other outside wall of a home. This will ensure that
clearance to combustibles is maintained within the cavity. Framing dimensions will need to be adjusted
to account for the enclosure nishing material thickness.
** With a 1/2" thick nishing material.
D
3 3/4”
4 1/4” **
D
E
E
Finishing Material
Measurements are taken from the body.
Sides, back and top 0"
3.3.1 MINIMUM CLEARANCE TO COMBUSTIBLES
3.3.2 FRAMING
D* 21"
E* 95"
NON-LOAD