5.1 MINIMUM CLEARANCE TO COMBUSTIBLES
* HORIZONTAL VENT SECTIONS - A minimum clearance of 1" (25mm) at the bottom and sides and 2" (51mm)
at the top of the vent pipe in all horizontal runs to combustibles is required except for clearances in appliance
enclosures, see "MINIMUM ENCLOSURE CLEARANCES" section. Use fi restop spacer W010-1777 (supplied).
* VERTICAL VENT SECTIONS - A minimum of 1" (25mm) all around the vent pipe on all vertical runs to
combustibles is required. Use fi restop spacer W500-0096 (not supplied).
Minimum clearance to combustible construction from appliance and vent surfaces:
Combustible Framing:
- 0" to stand-offs
- 1" (25mm) to bottom and sides of the vent pipe*
- 2" (51mm) to top of the vent pipe*
Combustible Finishing:
- 0" to rear
- 0" to front face top and sides
- 13" (330mm) recessed depth
Rear Vent:
- 39 1/8" (994mm) to enclosure top from base of the unit
- 45 1/8" (1146mm) to ceiling from base of the unit
Top Vent:
- 53 1/8" (1349mm) to enclosure top from base of the unit
- 53 1/8" (1349mm) to ceiling from base of the unit
DO NOT BUILD INTO THIS AREA - IT MUST BE LEFT CLEAR TO PROVIDE ADEQUATE CLEARANCE
FOR THE VENT. IN THIS 14" (356MM) WIDE AREA CENTRED ALONG THE FRONT OF THE APPLIANCE,
NO COMBUSTIBLES ARE ALLOWED.
!
WARNING
13 1/4"
337mm
1 1/2"
38mm
MAXIMUM
14"
356mm
MINIMUM
1 1/2"
38mm
MAXIMUM
COMBUSTIBLE
MATERIAL
NON-COMBUSTIBLE
BOARD REQUIRED
*KEEP FACING MATERIAL 1/4”(6mm) FROM SIDE OF
UNIT TO ACHIEVE OPENING WIDTH OF 20 1/4” (514mm).
NOTE: MUST BE MAINTAINED FOR THE FACING KIT
TO COVER THE OPENING
*20 1/4” (514mm)
3"
76mm
MINIMUM
3"
76mm
MINIMUM
34 1/8"
867mm
FINISHING
MATERIAL
OPENING
HEIGHT
MUST BE
*
* 1/4
"
6mm