5.2 MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES
The appliance requires a minimum enclosure height of 53 1/8" (1349mm) for a top vent, and 39 1/8" (994mm) for
a rear vent. For temperature requirements, the enclosure space around and above the appliance must be left
unobstructed.
** When terminating vertically on a top vented appliance, the height clearance can be reduced to 39 1/8” (994mm).
2"
51mm
1"
25mm
26 3/8"
670mm
MINIMUM
PLUS RISE *
1"
25mm
0” IF NON-COMBUSTIBLE
FINISHING IS USED SUCH
AS BRICK AND STONE.
BRICK
NON-COMBUSTIBLE
COMBUSTIBLE
6"
152mm
33 1/8"
841mm
39 1/8"
994mm
0” IF NON-COMBUSTIBLE
FINISHING IS USED SUCH
AS BRICK AND STONE.
BRICK
NON-COMBUSTIBLE
COMBUSTIBLE
2"
51mm
1"
25mm
1"
25mm
33 1/8"
841mm
6"
152mm
1"
25mm
53 1/8"
1349mm
20"
508mm
43 1/8"
1095mm
MINIMUM
PLUS RISE *
1/2"
13mm
* See "VENTING" section