GD19 Manual

W415-1351 / 08.29.14
7
EN
2.3 GENERAL INFORMATION
* When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of speci c
recommendations from the local authority having jurisdiction, the certi ed high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000ft (305m) .
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases, unless a certi ed kit is used.
Provide adequate accessibility clearance for servicing and operating the appliance.
Never obstruct the front opening of the appliance.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance
and shall be installed.
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION
AND QUALITY!
RATES AND EFFICIENCIES
NATURAL GAS PROPANE GAS
Altitude 0 - 4,500* 0 - 4,500*
Maximum Input 11,500 11,000
Maximum Output 8,600 8,250
Ef ciency 75% 75%
Minimum Inlet Gas Supply Pressure 4.5" (11mb) Water Column 11" (27mb) Water Column
Maximum Inlet Gas Supply Pressure 7" (17mb) Water Column 13" (32mb) Water Column
Manifold Pressure Under Flow Conditions 3.5" (9mb) Water Column 10" (25mb Water Column
2.4 RATING PLATE INFORMATION
W385-1976
NOT FOR USE WITH SOLID FUEL
GD19
GD19N
NATURAL GAS MODEL
CONFORMS TO / CONFORME AUX: ANSI Z21.50-2014, CERTIFIED TO / CERTIFIE CSA 2.22-2014 VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ.
DIRECT VENT VENTED GAS FIREPLACE APPROVED FOR BEDROOM, BATHROOM & BEDSITTING ROOM
INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE
CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED
STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280.
WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR
MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A.
FOYER À GAZ VENTILÉS À ÉVACUATION DIRECTE. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER,
UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION
CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ, EN
VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE ET DE CONSTRUCTION DE MAISONS
MANUFACTUREES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE
APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR
LES INSTALLATIONS DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A.
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG)
PRESSION AU COLLECTEUR: 3.5" D'UNE
COLONNE D'EAU(GN)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG)
PRESSION D'ALIMENTATION MIN: 4.5" D'UNE
COLONNE D'EAU (GN)
MAX. SUPPLY PRESSURE: 7" W.C. (NG)
PRESSION D'ALIMENTATION MAX: 7" D'UNE
COLONNE D'EAU (GN)
MANIFOLD PRESSURE: 10 INCHES W.C.(LP)
PRESSION AU COLLECTEUR: 10" D'UNE
COLONNE D'EAU (P)
MIN SUPPLY PRESSURE: 11" W.C. (LP)
PRESSION D'ALIMENTATION MIN: 11" D'UNE
COLONNE D'EAU (P)
MAX. SUPPLY PRESSURE: 13" W.C. (LP)
PRESSION D'ALIMENTATION MAX: 13" D'UNE
COLONNE D'EAU (P)
0-4500ft
11,500 BTU/h
8,000 BTU/h
55.9%
ALTITUDE / ELEVATION
INPUT / ALIMENTATION
REDUCED INPUT /
ALIMENTATION REDUITE
P4
FOR USE WITH GLASS DOORS CERTIFIED
WITH THIS UNIT ONLY. FOR USE ONLY WITH
BARRIER W565-0170. FOLLOW THE
INSTALLATION INSTRUCTIONS LOCATED IN
THE INSTALLATION MANUAL.
WARNING: DO NOT ADD ANY MATERIAL TO THE
APPLIANCE, WHICH WILL COME IN CONTACT
WITH THE FLAMES, OTHER THAN THAT SUPPLIED
BY THE MANUFACTURER WITH THE APPLIANCE.
THIS VENTED GAS FIREPLACE IS NOT FOR USE
WITH AIR FILTERS.
ELECTRICAL RATING: BLOWER KIT GS66, 115V
0.5AMP 60HZ THE APPLIANCE MUST BE VENTED
USING THE APPROPRIATE WOLF STEEL VENT KITS.
SEE OWNERS INSTALLATION MANUAL FOR VENTING
SPECIFICS. MINIMUM AND MAXIMUM VERTICAL
VENT LENGTHS ARE 3 FEET AND 35FEET
RESPECTIVELY.
MINIMUM AND MAXIMUM HORIZONTAL VENT
LENGTHS ARE 8 INCHES AND 20 FEET
RESPECTIVELY. PROPER REINSTALLATION AND
RESEALING IS NECESSARY AFTER SERVICING
THE VENT-AIR INTAKE SYSTEM.
DECORATIVE PRODUCT: NOT FOR USE AS A HEATING
APPLIANCE
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL:
UTILISER AVEC LES PORTES VITREES
HOMOLOGUEES SEULEMENT AVEC CETTE
UNITE. POUR UNE UTILISER SEULMENT AVEC
BARRIÈRE W565-0170. SUIVEZ LES INSTRUCTIONS
D'INSTALLATION SE TROUVENT DANS LE MANUEL
D'INSTALLATION.
AVERTISSEMENT: N'AJOUTEZ PAS A CET APPAREIL
AUCUN MATERIAU DEVANT ENTRER EN CONTACT
AVEC LES FLAMMES AUTRE QUE CELUI QUI EST
FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
CE FOYER À GAZ VENTILÉS NE DOIT PAS ÊTRE
UTILISÉ CONJOINTEMENT AVEC DES FILTRES À AIR.
CLASS:
SOUFFLERIE GS66, 115V 0.5AMP 60HZ
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT
L'ENSEMBLE D'EVACUATION PROPRE A
WOLF STEEL. REFERER AU MANUEL
D'INSTALLATION DE PROPRIETAIRE POUR
L'EVACUATION PRECISE. LES LONGUEURS
VERTICALES MINIMALES ET MAXIMALES
SONT3 PIEDS ET 35 PIEDS RESPECTIVEMENT.
UN COMBUSTIBLE SOLIDE NE DOIT PAS
ETRE UTILSE AVEC CET APPAREIL
LES LONGUEURS HORIZONTALES MINIMALES ET
MAXIMALES SONT 8 POUCES ET 20 PIEDS
RESPECTIVEMENT.
IL EST IMPORTANT DE BIEN REINSTALLER ET
RESCELLER L'EVENT APRES AVOIR ASSURE LE
MAINTIEN DU SYSTEME DE PRISE D'AIR.
PRODUIT DÉCORATIF: NE PAS UTILISER COMME APPAREIL
DE CHAUFFAGE.
DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
SERIAL NUMBER / NO. DESERIE
0-4500ft
11,000 BTU/h
55.9%
CDV19N
GD19P
CDV19P
TOP 0" MANTEL 2"*
FLOOR 0" RECESSED DEPTH 13"
SIDES 0" VENT 1”
BACK 0”
DESSUS 0" MANTEAU 2"*
PLANCHER 0" PROFONDEUR DE L’ENCLAVE 13"
COTES 0" ÉVENT 1”
ARRIÉRE 0”
TOP, SIDES & BACK: PER STAND OFF SPACERS
FOR FRAMING MATERIALS. FOR FINISHING
MATERIALS SEE OWNERS MANUAL.
DESSUS, COTES & ARRIERE: SELON LES ESPACEURS DE
DEGAGEMENT POUR LES MATERIAUX D’OSSATURE SELON
LE MANUEL DE PROPRIETAIRE POUR LES MATERIAUX
DE FINITION.
* MAXIMUM HORIZONTAL EXTENSION 2”. SEE INSTRUCTION MANUAL FOR GREATER EXTENSIONS.
* L’EXTENSION HORIZONTAL MAXIMALE 2”. REFERER AU MANUEL D’INSTRUCTION POUR DES EXTENSIONS
PLUS GRANDES.
PROPANE MODEL
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
9700539 (WSL) 4001657 (NGZ)
4001658 (NAC) 4001659 (WUSA)
RATING PLATE LOCATION: The rating label is located behind the control panel and is chained to the
appliance. DO NOT REMOVE.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
SAMPLE
DIO. APPR
NCES DE LA NORME
CANADA OU AUX ETATS
EES, TITRE 24 CFR, SECTION 3280
ER A LA NORME RELATIVE AU CR
DANS LES MAISONS MANU
EVATION
MENTATION
CED INPU
ATION REDUITE
P4
T
ATION AND
R SERVICING
R USE AS A HEATING
CE TO COMBUSTIBLE MATERIAL
LISER AVEC
HOMOLOGUEES S
UNITE
OUR UN
BARRIÈRE W5
'INSTALL
D'INST
AV
A
0-4500ft
11,000
GD19P
PL
MANTEL 2"*
RECESSED DEPTH 13"
VENT 1
P, SIDES & BACK: PER STAND O
OR FRAMING MATERIALS. FOR FIN
MATERIALS SEE OWNERS MANUA
UAL FOR GRE
OPANE M
016
4001659