Vertical installations may display a very active
ame. I
f
this appearance is not desirable, the vent exit must
be restricted using a restrictor vent kit. Refer to “ACCESORIES” in the “REPLACEMENTS” section for the
appropriate kit. This will reduce the velocity of the exhaust gases, slowing down the ame pattern and creating
a more traditional gentle ame appearance. Speci c instructions are included with the kit.
It’s important to periodically perform a visual check of the pilot and burner ames. Compare them to the
illustration provided. If any ames appear abnormal call a service person.
FLAME MUST ENVELOP
UPPER 3/8” (9.5mm) TO 1/2”
(12.7mm) OF FLAME SENSO
R
PILOT
BURNER
ELECTRODE
FLAME
SENSOR
3/8” - 1/2”
(9.5mm - 12.7mm)
54.1B
10.3 FLAME CHARACTERISTICS
10.4 RESTRICTING VERTICAL VENTS - MODEL GDS60-1