Minimum Mantel Clearances
WARNING! Mantel temperatures will rise above normal temperatures and may be hot to the
touch.
We recommend that all mantels are made from non-combusble material. If using combusble materials,
follow the chart below.
Note: When using paint or lacquer to nish the mantel, the paint or lacquer must be heat resistant to
prevent discolouraon.
GSS48 / GSS48ST
8” (203mm) Mantle
6”(152mm)
4”(102mm)
2”(51mm)
Top of Fireplace
24”
(610mm)
26”
(660mm)
22”
(559mm)
20”
(508mm)
23”
(584mm)
6”(152mm)
All material in shaded
area must be Non
Combusble. (including
framing, sheeng and
nishing materials).
NON COMBUSTIBLE
Drain Installaon (Recommended)
Although this replace is designed to operate outdoors safely, rain and other sources of moisture may
enter the replace area, which will cause water to collect inside the base of the unit within the replace
enclosure. When choosing a locaon for your replace, care must be taken to avoid areas where excessive
moisture or running water may be a problem.
To prevent moisture or water from collecng underneath the replace, the builder must provide a means
to drain water from under the replace, before posioning the replace in its locaon. It is recommended
that a sealed corrosion resistant drain pan with provisions for drainage be posioned underneath
the replace. The drain pan can be constructed from corrosion resistant metal, or other suitable
materials such as an ice and water shield membrane. A means of drainage out of the drain pan such as
piping or weep holes must also be provided. A slope of 1/4” (6mm) per foot towards the drain port is
recommended.
Note: When planning for the installaon of the replace the framing height must be increased to
accommodate a drain pan and any addional drainage piping required.
Note: The replace must be installed on a level surface to ensure proper drainage.