Installation Sheet
www.napoleongrills.com
4
EN
INPUT
MODEL FUEL ORIFICE SIZE MAX. INPUT Btu/Hr GAS INLET PRESSURES
GSS48 Natural Gas #25 55, 000 7.0” W.C.
GSS48 Propane Gas #43 55, 000 11.0” W.C.
Geng Started
1. Remove all of the parts from the carton. Use the parts list to ensure all necessary parts are included.
2. Do not destroy packaging unl the appliance has been installed and operates to your sasfacon.
3. Choose a locaon that meets the clearance to combusbles as outlined in this manual. Take into
consideraon the need for clear and easy access to the on/o valve AFTER the appliance is installed
and connected to the gas supply in order to safely turn o the burner.
4. Most stainless steel parts are supplied with a protecve plasc coang that must be removed prior
to using the appliance.
5. Read and follow all instrucons in this manual before installing or servicing this gas appliance.
If you have any quesons about assembly or appliance operaon, or if there are damaged or missing
parts please call our Customer Care Department at 1-866-820-8686 between 9 AM and 5 PM (Eastern
Standard Time).
WARNING! This appliance is designed for non-combusble enclosures only, and must be installed
and serviced by a qualied installer to local codes.
CAUTION! During unpacking and assembly we recommended you wear work gloves and safety glasses
for your protecon. Although we make every eort to make the assembly process as problem free and safe
as possible, it is characterisc of fabricated steel parts that the edges and corners might be sharp and could
cause cuts if handled incorrectly.
General nformaon
This gas appliance was tested and listed to Canadian and American Naonal Standards, ANSI Z21.97-
2012/
CSA 2.41-2012 “Standard for Outdoor Decorave Gas Appliance” and CGA 2.17-M91 (R2009) “Gas-Fired
Appliance for use at High Altude” by OMNI-Test Laboratories. When an appliance is for connecon to a
xed piping system, the installaon must conform with local codes, or in the absence of local codes, with
the Naonal Fuel Gas Code, ANSI Z233.1/NFPA 54, Internaonal Fuel Gas Code, Natural Gas and Propane
Installaon Code, CSA B149.1, or Propane Storage and Handling Code, B149.2, as applicable.
The appliance, when installed, must be electrically grounded in accordance with local codes, or in the
absence of local codes, with the Naonal Electrical Code, ANSI/NFPA 70 or the Canadian Electrical Code,
CSA C22.1.
This appliance should be installed and serviced by a qualied installer to conform with local codes.
Installaon pracces vary from region to region and it is important to know the specics that apply to
your area, for example: in Massachuses State:
• The appliance o valve must be a “T” handle gas cock.
• The exible connector must not be longer than 36 inches.
The appliance and its individual shut o valve must be disconnected from the gas supply piping system
during any pressure tesng of the system at test pressures in excess of 1/2 psig (3.5kPa).
This appliance must be isolated from the gas supply piping system by closing its individual manual shut o
valve during any pressure tesng of the gas supply piping system at test pressures equal to or less than
1/2 psig (3.5kPa).
• Always keep the appliance area clear and free
from combusble materials, gasoline, and
other ammable vapours and liquids.
• Do not locate appliance where it can get exces-
sively wet.
• Do not use this appliance if any part has been
under water. Immediately call a qualied
service technician to inspect the unit and to
replace any part of the control system and any
gas control, which has been underwater.