Full Product Manual
www.napoleongrills.com
7
EN
NaturalGasHook-Up
The piping up to the appliance is the responsibility of the installer. Connect the inlet valve to rigid pipe,
copper tube or an approved exible metal connector which complies with naonal and regional codes.
If using a gas hose (not supplied) connect the ared end of the hose to the connector on the end of the
inlet valve. Tighten using two wrenches. (Do not use thread sealer/pipe dope.) Leak test all joints prior to
using the appliance. Piping and valves upstream of the quick disconnect are not supplied. The installaon
must comply with naonal and regional codes. The gas supply pipe must be suciently sized to supply the
kW specied on the rang plate, based on the length of the piping run. The quick disconnect must not be
installed in an upward direcon and a readily accessible manual shut-o valve must be installed upstream
of, and as close to, the quick disconnect as is feasible.
Purgethegassupplylineofanytrappedairpriortotherstringoftheunit.
WARNING!
• The installaon must be performed by a licensed gas er, and all connecons must be leak tested
before operang the appliance.
• Ensure all hose connecons are ghtened using two wrenches. Do not use Teon tape or pipe dope
on any hose connecon.
• Ensure the hose does not contact any high temperature surfaces or it may melt and leak causing a
re.
• Locate the hose out of pathways where people may trip over it or in areas where the hose may be
subject to accidental damage.
• Leak test all the connecons using a soap and water soluon as per the leak tesng instrucons
found in the manual.