User Guide
5
www.napoleongrills.com
WARNING!
WARNING!
property, serious bodily injury, or death.
: This must be done before inial use, annually, and whenever any gas components are replaced
or serviced. Do not smoke while performing this test, and remove all sources of ignion. See Leak Tesng
Diagram for areas to check. Turn all burner controls to the o posion. Turn gas supply valve on.
-
installer.
-
Natural Gas Hook-Up
This natural gas grill is supplied with a 10 supply hose (complete with a quick disconnect) designed for natural
gas and cered for outdoor use. The gas grill is designed to operate at an inlet pressure of 7 inches water
column. Piping and valves upstream of the quick disconnect are not supplied. The installaon must comply
with CAN B149.1 Natural Gas and Propane installaon code in Canada, or to the Naonal Fuel Gas Code, ANSI
Z223.1 in the United States. The gas supply pipe must be sucient to supply this 106,500 BTU/hr gas grill.
The quick disconnect must not be installed in an upward direcon and a readily accessible manual shut-o
valve must be installed upstream of, and as close to, the quick disconnect as is feasible. The ared end of the
hose must be connected to the ng on the end of the ex tube as illustrated in the Natural Gas Hose Aach-
ment diagram. Tighten using two wrenches. (Do not use thread sealer/pipe dope.) These connecons must
be made by a licensed gas installer. Leak test all joints prior to using the gas grill.
WARNING!
The installaon must be performed by a licensed gas er, and all connecons must be leak tested before •
operang the grill.
Do not route hose underneath drip pan.•
Do not route hose between space in boom shelf and back panel.•
Do not route hose over top of back panel.•
Ensure all hose connecons are ghtened using two wrenches. Do not use teon tape or pipe dope on •
any hose connecon.
Ensure the hose does not contact any high temperature surfaces, or it may melt and leak causing a re.•
Do not use enclosure to store excess hose, as there is a greater chance of the hose contacng a hot sur-•
face, it may melt and leak causing a re.
Leak test all the connecons using a soap and water soluon, as per the leak tesng instrucons found in •
the this manual.