2.0  LOCATING APPLIANCE
2.1  UNPACKING AND TESTING APPLIANCE
Carefully remove the appliance from the box and remove the support brackets. Prior to installing the 
appliance, remove all packaging material and test to make sure the appliance operates properly by plugging 
the power supply cord into a conveniently located 120V,15 Amp minimum grounded outlet.
2.2  GROUNDING APPLIANCE
DUE TO HIGH TEMPERATURES, THIS ELECTRIC APPLIANCE SHOULD BE LOCATED OUT OF 
TRAFFIC. KEEP COMBUSTIBLE MATERIALS SUCH AS FURNITURE, PILLOWS, BEDDING, PAPERS, 
CLOTHES AND CURTAINS AT LEAST 36" FROM THE FRONT OF THE APPLIANCE.
NEVER LOCATE THIS ELECTRIC APPLIANCE WHERE IT MAY FALL INTO A BATHTUB OR OTHER 
WATER CONTAINER.
WEAR SAFETY GLOVES AND SAFETY GLASSES FOR PROTECTION DURING INSTALLATION AND 
MAINTENANCE.
TO PREVENT CONTACT WITH SAGGING OR LOOSE INSULATION, THE ELECTRIC APPLIANCE 
MUST NOT BE INSTALLED AGAINST VAPOR BARRIER OR EXPOSED INSULATION. LOCALIZED 
OVERHEATING COULD OCCUR AND A FIRE COULD RESULT.
DO NOT EXPOSE THE ELECTRIC APPLIANCE TO THE ELEMENTS (SUCH AS RAIN, ETC.)
96.1
GROUNDING METHODS
METAL SCREW
(A)
NOT ALLOWED IN CANADA
GROUNDING 
MEANS
ADAPTER
GROUNDING PIN
COVER OF 
GROUNDED
OUTLET BOX
(C)
(B)
This appliance is for use on 120 volts. The cord has a plug 
as shown in (A). An adapter as shown in (C) is available for 
connecting three-blade grounding type plugs to two-slot 
receptacles. The green grounding plug extending from the 
adapter must be connected to a permanent ground such as 
a properly grounded outlet box. The adapter should not be 
used if a three-slot grounded receptacle is available.
To disconnect appliance, turn controls to off, then remove 
plug from outlet. 
NOTE: Must be connected to a dedicated15 amp circuit. The 