Installation Guide

W415-2212 / F / 04.23.19
EN
18
installation
4.6 240V hard wiring installation (NEFL42 / 50 / 60 / 74 / 100 CHD only)
If it is necessary to hard wire this appliance. A qualifi ed electrician must remove the cord connection and wire
the appliance directly to the household wiring. The wire and double-pole power supply breaker must be rated for
240V minimum 15 amps.
This appliance must be electrically connected and grounded in accordance with local codes if hard wired. In the
absence of local codes, use the current CSA C22.1 Canadian Electrical Code in Canada or the current ANSI/
NFPA 70 National Electrical Code in the United States.
!
WARNING
Turn off the appliance completely and let cool before servicing. Only a qualifi ed service person should service
and repair this electric appliance.
There are 4 wires from the appliance junction that connect to the 240V power supply (breaker panel): 1 white
(neutral), 1 black (power L1), 1 red (power L2), and 1 green (ground).
note:
BLACK (L1)
WHITE (N)
YELLOW (N1)
YELLOW (N2)
GREEN (G)
(G)
(N)
(L1)
(L2)
RED (L2)
L
W
L
L
R
(G)
(N)
(L1
)
(L2)
REMOVE JUMPER WIRES!
White, black, red, and green wires:
Connect to 240V power supply.
4
6
1
1
-
:
1
0
8
&
3
+
6
/
$
5
*
0
/
'
*
3
&
1
-
"
$
&
GREEN (G)
GREEN (G)
RED (L2)
RED (L2)
BLACK (L1)
WHITE (N)
YELLOW (N2)
YELLOW (N1)
BLACK (L1)
WHITE (N)
240V
Failure to remove the two jumper wires may cause fi re!
WARNING