8.3 LIGhTING hEATER mANUALLY
Your heater can be lit manually without using the automatic igniter by following the procedure below.
● Press the ON / OFF button.
● Place a "handful" of pellets into the burn pot.
● Cover with a small amount of approved (non-volatile) fire starter gel.
● Light fire starter with a match and close the viewing door.
Heater may be hot.
Other than placing a handful of pellets in the burn pot for lighting manually, never feed pellets
through the glass viewing door. An "OVERFIRE" condition could occur, if more pellets enter the
firebox than what the feed tube can deliver. Pellets must only be burned within the burn pot.
!
WARNING
TP- LIGHTING HEATER MANUALLY_PELLET
TP - OPERATION PELLET
TP - LIGHTING INSTRUCTIONS_NPS45
8.4 LIGhTING INSTRUCTIONS
After filling the hopper with pellets, switch the control to manual so that you have full control of the heater until you have
familiarized yourself with its functions.
Do not try to operate your heater with the ash pan drawer, viewing door or hopper lid open. Safety switches will disable the
pellet feed auger.
● Push the ON / OFF button to initiate the start-up cycle.
● Once the start-up cycle has ended (approximately 12 to 15 minutes) adjustments can be made to the control.
NOTE: If the heater shuts off, empty the pellets from the burn pot and repeat steps 1 and 2.
8.5 CONTROLS
TITLE: LABEL, CONTROL PANEL NPS45
REVISION: A: LABEL THICKNESS II 06.18.08 B: LABEL SIZE II 07.17.08_JK
DWG#: W385-0425
DATE:
06.17.08
.010” CLEAR LEXAN
LABEL TO BE 2 5/8” X 5 5/8”
BACK VIEW OF LABEL - ADD ADHESIVE IN HATCHED AREAS
COLOURS TO BE WHITE ON BLACK BACKGROUND WITH RED FLAMES AND FAN AS ILLUSTRATED
HEAT, FAN, AUGER FEED, AND ON OFF TO HAVE A 1/32“ BORDER
7 WINDOWS - BORDER NOT REQUIRED
1 CUTOUT - BORDER NOT REQUIRED
PANTONE COLOUR #ED1C24
AUGER
FEED
ON
OFF
POWER
AUGER
AUTO
T-STAT
MANUAL
HEAT FAN
HEAT
MODE
W385-0425 / B
FAN
FRONT VIEW OF LABEL
BACK VIEW
OF LABEL
.250”
.500”
.250”
.406”
5.531”
2.625”
Windows
(x7)
Cutout
HATCHED AREA TO BE ADHESIVE
BACKED C/W PROTECTIVE
PAPER BACKING
.500”
A
B
B
RED LIGHTS
Solid
- Indicates set feed rates.
- When making fan adjustment, light
will indicate fan speed temporarily
and return to heat setting.
Flashing
- Indicates an operation failure.
HEAT ADJUSTMENT
Increases or decreases the heat level.
AUGER FEED
Speed feeding of pellets into the burn
pot.
GREEN LIGHT
Solid
- Normal operating mode.
Flashing
- Start-up or shut down cycle.
AMBER LIGHT
When on, the auger is turning.
OPERATING MODE
Sets the heaters operating mode.
FAN ADJUSTMENT
Increases or decreases the speed
of the convection fan.
ON / OFF
Used to turn the heater on or off.
FIGURE 8.5
8.3.1
8.3.2
8.3.3
8.3.4
8.4.1
8.4.2