Installation Guide

W415-0702 / 10.30.08
34
The more frequently you clean out the fly ash, the
more efficient your heater will burn.
A. Open the viewing door. See “OPEN MAIN
VIEWING DOOR” section.
B. Lift the burn pot out and set aside on a
non-combustible surface. Remove the
right and left louvres by lifting the
louvres up and out of the firebox
setting them on a
non-combustible surface.
The firebox becomes very hot during operation. Let the heater cool completely before
conducting service.
!
WARNING
LOUVRES
FIREBOX
AIR
HOUSING
EXHAUST MANIFOLD
OPENING
9.2 BI-WEEkLY (OR EvERY 10 BAGS OF PELLETS)
9.2.1 vACUUm FIREBOx
9.3 SEmI-ANNUALLY (OR EvERY TWO TONS OF PELLET)
9.3.1 vACUUm hOPPER
The firebox becomes very hot during operation. Let the heater cool completely before
conducting service.
Disconnect the power cord prior to conducting service.
The following section details extensive maintenance procedures. We strongly suggest these items be carried
out by a trained service technician, possibly by a service agreement set up with your dealer.
!
WARNING
NOTE: More frequent cleaning may be required depending on pellet quality.
Run the heater until the pellets run out, then open the hopper and vacuum out the entire hopper.
The dust and any other debris near the bottom should be removed to prevent excessive build-up.
TP - VACUUM FIREBOX_PELLET
TP - SEMI ANNUALLY_PELLET
TP - VACUUM HOPPER_PELLET
FIGURE 9.2.1a
FIGURE 9.2.1b
FIGURE 9.3.1