Owner Manual

EN
W415-1966 / 07.08.19
15
A. Ensure that the access cover plate has been installed.
B. Remove the on/off switch bracket and the cover plate
below it. The cover plate may now be discarded.
C. Decide which side of the blower housing you prefer the
on/off switch to be located on.
D. Remove the 2 screws from the top outer edge of the rear
appliance panel. The housing is mounted using these
two holes, as well as two other holes located in the rear
panel.
E. Mount and secure the blower housing using 4 screws.
Ensure that the on/off switch wires pass through the
appropriate slot located on either side of the blower
housing.
F. Remove the 2 screws from the side of the blower
housing that you want the switch to be located on and
re-secure the on/off switch.
Because the blower is thermally activated, when turned on, it will
automatically start approximately 15-30 minutes after lighting the
appliance and will run for approximately 30-45 minutes after the
appliance has been turned off. Use of the fan increases the output
of heat.
Drywall dust will penetrate into the blower bearings, causing
irreparable damage. Care must be taken to prevent drywall
dust from coming into contact with the blower or its compartment.
Any damage resulting from this condition is not
covered by the warranty policy.
SLOT
REMOVED SCREWS
6.0 blower installation
ACCESS PLATE
COVER
PLATE
ON/OFF
SWITCH
BRACKET