Installation Manual
Table Of Contents
- W415-1642_Ae
- W415-1642_Af
W415-1642 / A / 08.25.16
20
EN
5.1 FINISHING MATERIAL
USE METAL STUDS WHEREVER
NON-COMBUSTIBLE FACING IS REQUIRED
NON-COMBUSTIBLE
BOARD FROM THE SIDE
OF THE APPLIANCE TO
COMBUSTIBLES; AS
MEASURED FROM THE
SIDE OF THE FACEPLATE.
NON-COMBUSTIBLE BOARD
MIN. ENCLOSURE
CEILING HEIGHT 96”
(2438MM).
COMBUSTIBLE
FACING AND WOOD
FRAMING MAY
START AT 8’ (2.4M)
ABOVE THE BASE OF
THE APPLIANCE.
FACE MUST HAVE A
MIN. 8’ (2.4M) HEIGHT
OF NON-COMBUSTIBLE
BOARD DEPENDING
UPON THE CEILING
HEIGHT
46 3/8"
(1178mm)
6" (152mm)
FACEPLATE
WARNING: Screws used to fasten finishing materials to the face of the appliance above the guillotine
screen and door must not penetrate more than 1/2" (13mm) into the sheet metal front panels. Refer to