WARNING!
part of the gas system is replaced.
WARNING!


: This must be done before inial use, annually, and whenever any gas components are
replaced or serviced. Do not smoke while performing this test, and remove all sources of ignion. See Leak
Tesng Diagram for areas to check. Turn all burner controls to the o posion. Turn gas supply valve on.
Brush a half-and-half soluon of liquid soap and water onto all joints and connecons of the regulator,
hose, manifolds and valves.
Bubbles will indicate a gas leak. Either ghten the loose joint or have the part replaced with one
recommended by the Napoleon Customer Soluons department and have the grill inspected by a cered
gas installer.
If the leak cannot be stopped, , disconnect it, and have the grill
inspected by a cered gas installer or dealer. Do not use the grill unl the leak has been corrected.
STOP
WARNING!
The installaon must be performed by a licensed gas er, and all connecons must be leak tested
before operang the grill.
Do not route hose underneath the drip pan.
Do not route hose between boom shelf space and back panel.
Do not route hose over top of rear panel.
Ensure all hose connecons are ghtened using two wrenches. Do not use Teon tape or pipe dope
on any hose connecon.
Ensure the hose does not contact any high temperature surfaces or it may melt and leak causing a
re.
Leak test all the connecons using a soap and water soluon as per the leak tesng instrucons found
in the manual.
The outdoor cooking gas appliance and its individual shuto valve must be disconnected from the gas
supply piping system during any pressure tesng of that system at test pressures in excess of 0.5 psi
(3.5 kPa).
The outdoor cooking gas appliance must be isolated from the gas supply piping system by closing its
individual manual shuto valve during any pressure tesng of the gas supply piping system at test
pressures equal to or less than 1/2 psi (3.5 kPa).