Product Brochure

24
Rated BTU/h with softwood test fuel (for emissions only) - no refueling. *
Wolf Steel Ltd. own test results showing realistic BTU’s using hardwood logs with regular refueling. Heat output will differ on chimney draft as well as type, moisture content and size of wood. **
Figures may vary with individual conditions such as floor plan layout, insulation value/heat loss of the house, geographical location and firewood used. ***
Banff
1400
Shown on pages 4 & 5
Model BTU
Heat
Output*
BTU
Heat Output
(High
Burn)**
Firebox
Capacity
(cu. ft.)
Area Heated
(sq. ft.)***
Burn Time
(Hours)
Log Size
(Max)
Emissions
(Grams Per
Hour)
Flue Diameter Catalytic
Combustor
Mobile Home
Approved
Blower Kit
Available
Top Rear
1400C
11,400 -
41,300
70,000 2.25
800 -
2,000+
9 hrs 18" 3.5 6" N/A No
Yes
(US Only)
Yes
Installation Clearances Corner Rear Sides
Single wall chimney connector
from stove to combustibles
6" 12" 12"
With approved double wall pipe
from stove to combustibles
4" 6" 10"
Weight
of Bricks
Weight
Without
Bricks,
Doors or Top
145 lbs 305 lbs
28
1
/
2
28 1/2"
724mm
6 3/4"
171mm
27"
686mm
FRONT VIEW SIDE VIEW TOP VIEW
28"
711mm
14"
356mm
If the stove is to be installed on a combustible floor, it must be placed on an approved non-combustible hearth pad, that extends 8" (200mm) beyond the stove sides and back, and 18" (455mm) to the front. Clearances can be reduced with shielding acceptable to local authorities. Reduced installation must comply with NFPA211 or CAN/CSA-B365.
Banff
110 0
Shown on pages 4 & 5
Model BTU
Heat
Output*
BTU
Heat Output
(High
Burn)**
Firebox
Capacity
(cu. ft.)
Area Heated
(sq. ft.)***
Burn Time
(Hours)
Log Size
(Max)
Emissions
(Grams Per
Hour)
Flue Diameter Catalytic
Combustor
Mobile Home
Approved
Blower Kit
Available
Top Rear
1100C
11,700 -
42,200
55,000 1.7
600 -
1,600+
7 hrs 18" 4.1 6" N/A No Yes Yes
Installation Clearances Corner Rear Sides
Single wall chimney connector
from stove to combustibles
6" 10" 12"
With approved double wall pipe
from stove to combustibles
2" 6" 10"
Weight
of Bricks
Weight
Without
Bricks,
Doors or Top
110 lbs 215 lbs
If the stove is to be installed on a combustible floor, it must be placed on an approved non-combustible hearth pad, that extends 8" (200mm) beyond the stove sides and back, and 18" (455mm) to the front. Clearances can be reduced with shielding acceptable to local authorities. Reduced installation must comply with NFPA211 or CAN/CSA-B365.
28 1/2"
724mm
6 3/4"
171mm
22 1/2"
572mm
FRONT VIEW SIDE VIEW TOP VIEW
28"
711mm
14"
356mm
28
1
/
2