Product Brochure

25
Independence
Shown on pages 6 & 7
S1 Small Stove
Shown on pages 8 & 9
If the stove is to be installed on a combustible floor, it must be placed on an approved non-combustible hearth pad, that extends 8" (200mm) beyond the stove sides and back, and 18" (455mm) to the front. Clearances can be reduced with shielding acceptable to local authorities. Reduced installation must comply with NFPA211 or CAN/CSA-B365.
If the stove is to be installed on a combustible floor, it must be placed on an approved non-combustible hearth pad, that extends 8" (200mm) beyond the stove sides and back, and 18" (455mm) to the front. Clearances can be reduced with shielding acceptable to local authorities. Reduced installation must comply with NFPA211 or CAN/CSA-B365.
Model BTU
Heat
Output*
BTU
Heat Output
(High
Burn)**
Firebox
Capacity
(cu. ft.)
Area Heated
(sq. ft.)***
Burn Time
(Hours)
Log Size
(Max)
Emissions
(Grams Per
Hour)
Flue Diameter Catalytic
Combustor
Mobile Home
Approved
Blower Kit
Available
Top Rear
1450
11,500 -
33,600
70,000 2.25
800 -
2,000+
9 hrs 18" 3.5 6" N/A No No Yes
Model BTU
Heat
Output*
BTU
Heat Output
(High
Burn)**
Firebox
Capacity
(cu. ft.)
Area Heated
(sq. ft.)***
Burn Time
(Hours)
Log Size
(Max)
Emissions
(Grams Per
Hour)
Flue Diameter Catalytic
Combustor
Mobile Home
Approved
Blower Kit
Available
Top Rear
S1
11,700 -
42,200
55,000 1.7
600 -
1,600+
7 hrs 18" 4.1 6" N/A No Yes Yes
Installation Clearances Corner Rear Sides
Single wall chimney connector
from stove to combustibles
6" 12" 12"
With approved double wall pipe
from stove to combustibles
4" 6" 10"
Installation Clearances Corner Rear Sides
Single wall chimney connector
from stove to combustibles
6" 10" 16"
With approved double wall pipe
from stove to combustibles
2" 6" 6"
Weight
of Bricks
Weight
Without
Bricks or
Doors
145 lbs 250 lbs
Weight
of Bricks
Weight
Without
Bricks or
Doors
110 lbs 215 lbs
7 1/4"
184mm
22”
559mm
Ø
6 "
152mm
12 3/4"
324mm
25 1/2"
648mm
31 1/4"
793mm
7 3/8"
187mm
26 1/2"
673mm
7 1/4"
184mm
25 1/2"
648mm
12 3/4"
324mm
Ø
6 "
152mm
S1 ILLUSTRATED
25 1/2"
648mm
12 3/4"
324mm
Ø
6 "
152mm
S4 ILLUSTRATED
34"
864mm
S9 ILLUSTRATED
34"
864mm
34"
864mm
7 1/4"
184mm
22”
559mm
Ø
6 "
152mm
12 3/4"
324mm
25 1/2"
648mm
31 1/4"
793mm
7 3/8"
187mm
26 1/2"
673mm
7 1/4"
184mm
25 1/2"
648mm
12 3/4"
324mm
Ø
6 "
152mm
S1 ILLUSTRATED
25 1/2"
648mm
12 3/4"
324mm
Ø
6 "
152mm
S4 ILLUSTRATED
34"
864mm
S9 ILLUSTRATED
34"
864mm
34"
864mm
FRONT VIEW SIDE VIEW TOP VIEW
33 1/4"
845mm
7 1/2"
191mm
27"
686mm
25 1/2"
648mm
12 3/4"
324mm
6"
152mm
DIA.
S4 Medium Stove
Shown on pages 8 & 9
If the stove is to be installed on a combustible floor, it must be placed on an approved non-combustible hearth pad, that extends 8" (200mm) beyond the stove sides and back, and 18" (455mm) to the front. Clearances can be reduced with shielding acceptable to local authorities. Reduced installation must comply with NFPA211 or CAN/CSA-B365.
Model BTU
Heat
Output*
BTU
Heat Output
(High
Burn)**
Firebox
Capacity
(cu. ft.)
Area Heated
(sq. ft.)***
Burn Time
(Hours)
Log Size
(Max)
Emissions
(Grams Per
Hour)
Flue Diameter Catalytic
Combustor
Mobile Home
Approved
Blower Kit
Available
Top Rear
S4
11,400 -
41,300
70,000 2.25
800 -
2,000+
9 hrs 18" 3.5 6" N/A No
Yes
(US Only)
Yes
Installation Clearances Corner Rear Sides
Single wall chimney connector
from stove to combustibles
6" 10" 16"
With approved double wall pipe
from stove to combustibles
4" 6" 16"
Weight
of Bricks
Weight
Without
Bricks or
Doors
145 lbs 250 lbs
7 1/4"
184mm
22”
559mm
Ø
6 "
152mm
12 3/4"
324mm
25 1/2"
648mm
31 1/4"
793mm
7 3/8"
187mm
26 1/2"
673mm
7 1/4"
184mm
25 1/2"
648mm
12 3/4"
324mm
Ø
6 "
152mm
S1 ILLUSTRATED
25 1/2"
648mm
12 3/4"
324mm
Ø
6 "
152mm
S4 ILLUSTRATED
34"
864mm
S9 ILLUSTRATED
34"
864mm
34"
864mm
7 1/4"
184mm
22”
559mm
Ø
6 "
152mm
12 3/4"
324mm
25 1/2"
648mm
31 1/4"
793mm
7 3/8"
187mm
26 1/2"
673mm
7 1/4"
184mm
25 1/2"
648mm
12 3/4"
324mm
Ø
6 "
152mm
S1 ILLUSTRATED
25 1/2"
648mm
12 3/4"
324mm
Ø
6 "
152mm
S4 ILLUSTRATED
34"
864mm
S9 ILLUSTRATED
34"
864mm
34"
864mm
* Rated BTU/h with softwood test fuel (for emissions only) - no refueling
** Wolf Steel Ltd. own test results showing realistic BTU’s using hardwood logs with regular refueling. Heat output will differ on chimney draft as well as type, moisture content and size of wood.