Owners Guide - IR3GN

26
21
3
/
8
11
11
1
/
2
16
5
/
8
33
5
/
8
34
3
/
4
12
1
/
2
16
5
/
8
25
1
/
4
30”
48”
24
1
/
4
24
1
/
2
21
3
/
8
11
11
1
/
2
16
5
/
8
33
5
/
8
34
3
/
4
12
1
/
2
16
5
/
8
25
1
/
4
30”
48”
24
1
/
4
24
1
/
2
21
3
/
8
11
11
1
/
2
16
5
/
8
33
5
/
8
34
3
/
4
12
1
/
2
16
5
/
8
25
1
/
4
30”
48”
24
1
/
4
24
1
/
2
Figures may vary with individual conditions such as floor plan layout, insulation value/heat loss of the house and geographical location.
Measurements to be used as a guide only. Consult your owner’s manual for complete and up-to-date installation instructions and proper clearances to combustible materials.
XIR4
Shown on pages 8 & 9
GDI30G
Shown on pages 10 & 11
GDI30
Shown on pages 12 & 13
Model BTU’s (Input) Venting Height Front Width Depth Glass
Type
Glass Size Viewing Area
(sq. in.)
Efficiencies Blower Mobile Home
Certified
Electronic
Ignition
Natural Gas Propane Actual
Minimum
Opening
Actual
Minimum
Opening
Actual
Minimum
Opening
Height Width EnerGuide AFUE Steady State
XIR4 16 - 40,000 15 - 40,000 3" 24 1/2 25" 34 3/4" 34 1/4" 16 5/8" 17" Ceramic 20 5/8" 31" 560 68.9% 72.4% 83% Standard Yes Yes
Model BTU’s (Input) Venting Height Front Width Depth Glass
Type
Glass Size Viewing Area
(sq. in.)
Efficiencies Blower Mobile Home
Certified
Electronic
Ignition
Natural Gas Propane Actual
Minimum
Opening
Actual
Minimum
Opening
Actual
Minimum
Opening
Height Width EnerGuide AFUE Steady State
GDI30G 15 - 24,500 15 - 24,500 3" 21 3/4" 22" 30 1/16" 28" 17 7/8" 18" Ceramic 14" 28 1/2" 399 64.5% - 85% Standard Yes Yes
Model BTU’s (Input) Venting Height Front Width Depth Glass
Type
Glass Size Viewing Area
(sq. in.)
Efficiencies Blower Mobile Home
Certified
Electronic
Ignition
Natural Gas Propane Actual
Minimum
Opening
Actual
Minimum
Opening
Actual
Minimum
Opening
Height Width EnerGuide AFUE Steady State
GDI30 15 - 24,500 15 - 24,500 3" 21 3/4" 22" 30 1/16" 28" 17 7/8" 18" Ceramic 14" 28 1/2" 399 64.5% 60.02% 85% Standard Yes No
Certified and tested under Canadian and American National standards: CSA 2.33, ANSI Z21.88 for vented gas fireplace heaters.
Certified and tested under Canadian and American National standards: CSA 2.22, ANSI Z21.50 for vented gas fireplaces.
Certified and tested under Canadian and American National standards: CSA 2.22, ANSI Z21.50 for vented gas fireplaces.
25
1
/
2
7
1
/
4
15
1
/
8
42”
30
1
/
16
11
1
/
8
27
1
/
2
19
5
/
8
13
3
/
4
17
7
/
8
20
3
/
8
EXHAUST (3” DIA)
AIR INLET (3” DIA)
1
3
/
8
GAS INLET
ELECTRICAL INLET
LEFT SIDE
13
3
/
4
21
3
/
4
23
1
/
8
GDI-30G
25
1
/
2
7
1
/
4
15
1
/
8
42”
30
1
/
16
11
1
/
8
27
1
/
2
19
5
/
8
13
3
/
4
17
7
/
8
20
3
/
8
EXHAUST (3” DIA)
AIR INLET (3” DIA)
1
3
/
8
GAS INLET
ELECTRICAL INLET
LEFT SIDE
13
3
/
4
21
3
/
4
23
1
/
8
GDI-30G
25
1
/
2
7
1
/
4
15
1
/
8
42”
30
1
/
16
11
1
/
8
27
1
/
2
19
5
/
8
13
3
/
4
17
7
/
8
20
3
/
8
EXHAUST (3” DIA)
AIR INLET (3” DIA)
1
3
/
8
GAS INLET
ELECTRICAL INLET
LEFT SIDE
13
3
/
4
21
3
/
4
23
1
/
8
GDI-30G
27
1
/
2
(30
1
/
2
”)
43”
(49”)
11
1
/
8
30
1
/
16
27
1
/
4
19
5
/
8
13
3
/
4
17
7
/
8
18
3
/
4
1
3
/
8
5
1
/
4
13
3
/
4
21
3
/
4
23
1
/
8
GAS INLET
ELECTRICAL INLET
LEFT SIDE
EXHAUST (3” DIA)
AIR INLET (3” DIA)
GDI-30
27
1
/
2
(30
1
/
2
”)
43”
(49”)
11
1
/
8
30
1
/
16
27
1
/
4
19
5
/
8
13
3
/
4
17
7
/
8
18
3
/
4
1
3
/
8
5
1
/
4
13
3
/
4
21
3
/
4
23
1
/
8
GAS INLET
ELECTRICAL INLET
LEFT SIDE
EXHAUST (3” DIA)
AIR INLET (3” DIA)
GDI-30
27
1
/
2
(30
1
/
2
”)
43”
(49”)
11
1
/
8
30
1
/
16
27
1
/
4
19
5
/
8
13
3
/
4
17
7
/
8
18
3
/
4
1
3
/
8
5
1
/
4
13
3
/
4
21
3
/
4
23
1
/
8
GAS INLET
ELECTRICAL INLET
LEFT SIDE
EXHAUST (3” DIA)
AIR INLET (3” DIA)
GDI-30
21
3
/
8
11
11
1
/
2
16
5
/
8
33
5
/
8
34
3
/
4
12
1
/
2
16
5
/
8
25
1
/
4
30”
48”
24
1
/
4
24
1
/
2