Installation Guide

Table Of Contents
W415-1344 / A / 12.14.16
6
EN
2.4 GENERAL INFORMATION
4.12A
THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to
conformwithlocalcodes.Installationpracticesvaryfromregiontoregionanditisimportanttoknowthe
specificsthatapplytoyourarea,forexampleinMassachusettsState:
• Thisproductmustbeinstalledbyalicensedplumberorgasfitterwheninstalledwithinthecommonwealth
ofMassachusetts.
• Theappliancedampermustberemovedorweldedintheopenpositionpriortoinstallationofanappliance
insertorgaslog.
• Theapplianceoffvalvemustbea“T”handlegascock.
• Theflexibleconnectormustnotbelongerthan36inches(91.4cm).
• ACarbonMonoxidedetectorisrequiredinallroomscontaininggasfiredappliances.
• Theapplianceisnotapprovedforinstallationinabedroomorbathroomunlesstheunitisadirectvent
sealedcombustionproduct.
Theinstallationmustconformwithlocalcodesor,in
absenceoflocalcodes,theNationalGasandPropane
InstallationCodeCSAB149.1inCanada,ortheNational
FuelGasCode,ANSIZ223.1/NFPA54intheUnited
States.Suitableformobilehomeinstallationifinstalledin
accordancewiththecurrentstandardCAN/CSAZ240MH
Series,forgasequippedmobilehomes,inCanadaor
ANSIZ223.1andNFPA54intheUnitedStates.
Someapplianceshaveoptionalfansorblowers.Ifanoptionalfanorblowerisinstalled,thejunctionboxmust
beelectricallyconnectedandgroundedinaccordancewithlocalcodes,usethecurrentCSAC22.1Canadian
ElectricalCodeinCanadaortheANSI/NFPA70NationalElectricalcodeintheUnitedStates.
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certied in the U.S.
by the National Fireplace
Institute
®
(NFI) as NFI Gas
Specialists
www.ncertied.org
ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT,
WITH THE GLASS DOOR OPENED OR REMOVED.
PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE.
PROVIDE ADEQUATE VENTILATION.
NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.
OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48 INCHES
(121.9cm) FROM THE FRONT FACE OF THE APPLIANCE.
SURFACES AROUND AND ESPECIALLY ABOVE THE APPLIANCE CAN BECOME HOT. AVOID CONTACT
WHEN THE APPLIANCE IS OPERATING.
FIRE RISK. EXPLOSION HAZARD.
HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE PRESSURE TESTING GAS
LINE AT TEST PRESSURES ABOVE 1/2 PSIG. CLOSE THE MANUAL SHUT-OFF VALVE BEFORE PRESSURE
TESTING GAS LINE AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSIG (35mb).
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE.
USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTING
COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.
THE APPLIANCE MUST NOT BE OPERATED AT TEMPERATURES BELOW FREEZING (32°F / 0°C).
ALLOW THE APPLIANCE TO WARM TO ABOVE FREEZING PRIOR TO OPERATION.
!
WARNING
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
XIR4-1
NG P
Altitude (FT) 0-4,500 0-4,500
Max. Input (BTU/HR) 40,000 40,000
Max. Output (BTU/HR) 33,200 33,200
Efficiency (w/the fan on) 83% 83%
A.F.U.E. (maximum value) 79% 79%
Min. Inlet Gas Supply Pressure 4.5" Water Column
(11mb)
11" Water Column
(27mb)
Max. Inlet Gas Supply Pressure 13" Water Column
(32mb)
13" Water Column
(32mb)
Manifold Pressure (Under Flow Conditions) 3.5" Water Column
(9mb)
10" Water Column
(25mb)
When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specific
recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000ft (305m). Expansion / contraction noises during heating
up and cooling down cycles are normal and to be expected.
This appliance is not approved for closet or recessed installations. It is approved for bathroom, bedroom
and bed-sitting room installations and is suitable for mobile homes. The natural gas model is suitable for
installation in a mobile home that is permanently positioned on its site and fuelled with natural gas.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance
and must be installed.
68.9%
XIR4-1