Fuel Conversion Kit Instruction Guide

LV38-1 illustrated.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically
approved with this appliance may result in property damage or personal injury.
CAUTION: Before proceeding with conversion the gas supply must be shut off prior to disconnecting the electrical power.
1. Remove the safety barrier, door trim and glass door. Remove existing media and media trays. Set aside.
2. Disengage the air shutter adjustment rod by pushing the smaller end of the rod to the left then push towards the back of
the appliance until the rod clears the rubber grommet (Fig. 1). The rubber grommet must stay in place.
3. Remove the screws that secure the entire burner assembly in place (screw counts vary by appliance size) (Fig. 2). Lift the
entire burner assembly up and out of the appliance. Remove the air shutter adjustment rod. Set both aside.
4. Using a deep socket wrench, remove the orifice from within the firebox and replace with the orifice supplied.
5. Remove the two screws from the valve regulator and remove the regulator, replace with the one supplied (Fig. 2).
6. Remove the pilot spring clip then the pilot hood from the pilot assembly by pulling vertically. Use a
5
/
32
” Allen key to
unscrew the injector. Replace the pilot injector with the one supplied (Fig. 3). Re-assemble the pilot hood onto the
assembly and reattach the spring clip ensuring key position for proper alignment.
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions
and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions
is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage,
personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The
installation is not proper and complete until the operation of the converted appliance is checked as specified in the
owner instructions supplied with the kit.
FUEL CONVERSION KITS FOR MODELS LV38-1 / LV50-2 / LV62
These kits are for use at altitudes of 0 to 4,500 feet.
INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOME OWNER.
CHECK THE BOXES TO INDICATE THAT THE CORRESPONDING STEPS HAVE BEEN COMPLETED.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleonreplaces.com
W415-1782 / B / 09.28.17
Figure 1
We strongly recommend converting your appliance prior to final installation and removing porcelain panels for conversion.
important:
Kit W175-0642, Natural Gas to Propane Includes;
1 Regulator
1 #53 Burner orifice
1 Propane burner tube
LV38-1
Kit W175-0644, Natural Gas to Propane Includes;
1 Regulator
1 #52 Burner orifice
1 Propane burner tube
LV50-2
Kit W175-0646, Natural Gas to Propane Includes;
1 Regulator
1 #51 Burner orifice
1 Propane burner tube
LV62
1 Propane pilot injector
1 Conversion data label
1 Air shutter adjustment rod
1 Propane pilot injector
1 Conversion data label
1 Air shutter adjustment rod
1 Propane pilot injector
1 Conversion data label
1 Air shutter adjustment rod
Figure 2