Datasheet

Automotive Grade, Fully Integrated, Hall Effect-Based Linear Current Sensor IC
with 2.1 kVRMS Voltage Isolation and a Low-Resistance Current Conductor
ACS714
2
Allegro MicroSystems, LLC
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000
www.allegromicro.com
the conductive path are electrically isolated from the signal leads
(pins 5 through 8). This allows the ACS714 to be used in applications
requiring electrical isolation without the use of opto-isolators or
other costly isolation techniques.
The ACS714 is provided in a small, surface mount SOIC8 package.
The leadframe is plated with 100% matte tin, which is compatible
with standard lead (Pb) free printed circuit board assembly processes.
Internally, the device is Pb-free, except for flip-chip high-temperature
Pb-based solder balls, currently exempt from RoHS. The device is
fully calibrated prior to shipment from the factory.
Description (continued)
TÜV America
Certificate Number:
U8V 06 05 54214 010
Parameter Specification
Fire and Electric Shock
CAN/CSA-C22.2 No. 60950-1-03
UL 60950-1:2003
EN 60950-1:2001
Selection Guide
Part Number
Optimized Range, I
P
(A)
Sensitivity, Sens
(Typ) (mV/A)
T
A
(°C)
Packing*
ACS714ELCTR-05B-T ±5 185
–40 to 85
Tape and reel, 3000 pieces/reel
ACS714ELCTR-20A-T ±20 100
ACS714ELCTR-30A-T ±30 66
ACS714LLCTR-05B-T ±5 185
–40 to 150
ACS714LLCTR-20A-T ±20 100
ACS714LLCTR-30A-T ±30 66
ACS714LLCTR-50A-T ±50 40
*Contact Allegro for additional packing options.
Absolute Maximum Ratings
Characteristic Symbol Notes Rating Units
Supply Voltage V
CC
8V
Reverse Supply Voltage V
RCC
–0.1 V
Output Voltage V
IOUT
8V
Reverse Output Voltage V
RIOUT
–0.1 V
Output Current Source I
IOUT(Source)
3mA
Output Current Sink I
IOUT(Sink)
10 mA
Overcurrent Transient Tolerance I
P
1 pulse, 100 ms 100 A
Nominal Operating Ambient Temperature T
A
Range E –40 to 85 ºC
Range L –40 to 150 ºC
Maximum Junction Temperature T
J
(max) 165 ºC
Storage Temperature T
stg
–65 to 170 ºC
Isolation Characteristics
Characteristic Symbol Notes Rating Unit
Dielectric Strength Test Voltage* V
ISO
Agency type-tested for 60 seconds per
UL standard 60950-1, 1st Edition
2100 VAC
Working Voltage for Basic Isolation V
WFSI
For basic (single) isolation per UL standard
60950-1, 1st Edition
354 VDC or V
pk
Working Voltage for Reinforced Isolation V
WFRI
For reinforced (double) isolation per UL standard
60950-1, 1st Edition
184 VDC or V
pk
* Allegro does not conduct 60-second testing. It is done only during the UL certification process.