user manual

NI USB-9421 User Guide and Specifications 12 ni.com
Figure 7. Pin Assignments
Connecting Devices to the NI USB-9421
The NI USB-9421 has sinking inputs, meaning that when current goes
through or voltage is applied to the DI terminal or pin, DI provides a path
to ground for the current or voltage. The NI USB-9421 internally limits
current signals connected to DI. For more information about input current
protection, refer to the Specifications section.
You can connect 2-, 3-, and 4-wire sourcing-output devices to the
NI USB-9421. A sourcing-output device drives current or applies voltage
to DI. An example of a sourcing-output device is a PNP open collector.
Connect the output of the sourcing-output device to DI on the
NI USB-9421. Connect the common of the external device to the COM
terminal or pin. Figure 8 shows a possible configuration.