Network Card User Manual

Chapter 2 Installation
© National Instruments Corporation 2-5 GPIB-SCSI-A for Solaris
Configuration Switch Settings for SW2
The DIP switch at location SW2 on the rear panel (see Figure 2-1) is used
to configure the mode of operation for the GPIB-SCSI-A. These switch
settings should not be changed for use with the Sun SPARC system.
Figure 2-3 shows the factory default settings. Make sure that these switches
are set as shown in Figure 2-3. If they are not, set these switches as
indicated.
Figure 2-3.
SW2 Default Mode Switch Settings
Table 2-3 shows the factory default configurations of the eight switches
for SW2.
Table 2-3. Factory Default Configurations for SW2
Switch Position Indication
13 OFF Reserved and should remain OFF
4 ON Double buffering is enabled
5 OFF GPIB-SCSI-A completes all data requests
to the count specified
6 ON GPIB-SCSI-A buffers data during data
transfer commands
7 ON GPIB-SCSI-A neither notices nor reports
SCSI parity errors
8 OFF Operating in S (SCSI) mode
SW2
12345678
9120
O
N
CTS 206-8
GS.book Page 5 Tuesday, June 12, 2001 2:17 PM