Understanding the Error Code
Error
Code
Condition Corrective Action
E01
System senses battery voltage is low
and has shutdown.
Recharge battery immediately and restart
unit.
E02
System senses battery voltage is high
and has shutdown.
Check battery voltage or if any external high
voltage DC source is connected to solar
charge port.
E03
System AC output is overloaded or
short circuited and has shutdown.
Check load connected to AC output. Reduce
load and restart the unit.
E04
System senses high internal
temperature and has shutdown
Turn unit off. Wait for 15 minutes before
restarting. Check if any object is blocking the
ventilation of unit.
E05
System warns battery voltage is low
and will shut down shortly
Recharge battery as soon as possible or
system will shut down shortly.
E06
System warns AC load connected is
close to overload shutdown limit.
Check load connected to AC output. Reduce
load.
E07
System warns of high internal
temperature and will shut down shortly.
Reduce load. Check if any object is blocking
the ventilation of unit.
E08 -
09
Not used
E10
Internal battery is overcharged
Check battery voltage or if any external high
voltage is connected to solar charge port
Estimated Run time of AC Load
Following run times are estimates. Actual run times may vary.
Load
Estimate
Consumption
Estimate Run time
400W
800W
Cordless Phone
5W
55 hrs
65 hrs
Home Alarm System
5W
55 hrs
65 hrs
Clock/Radio
8W
34 hrs
40 hrs
Table Lamp
40W
7.2 hrs
8.5 hrs
Table Lamp
60W
4.6 hrs
5.5 hrs
Energy Saving Light (5x17W)
85W
3.5 hrs
4.2 hrs
Solid red
“E01-E10”
Error on unit is detected. AC output is
disconnected. See Trouble shooting section.
Full
Automatic
Silent
In1,Al0
Same as “Full Automatic” mode but with audio alarm mute if error occurs. The
unit fault protection features remain active.
Backup
Disable
In0,Ch1,Al1
Solid
green
“Ful”
AC output is supplied by utility power. Internal
battery is fully charged.
Flashing
green
Battery
capacity in %
AC output is supplied by utility power. Charging
of internal battery by 2A charger is in progress.
Backup
Disable
with Alarm
Disable
In0,Ch1,Al0
Same as “Backup Disabled” mode but with audio alarm mute. The unit fault
protection features remain active.