Solar Generator 1800 USER MANUAL ENJOY THE FREEDOM OF USING SOLAR POWER
For safe and optimum performance, the Solar Generator 1800 must be used properly. Carefully read and follow all instructions and guidelines in this manual and pay special attention to the CAUTION and WARNING statements. Note: PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE Because the unit contains a large battery capacity, upon receiving it, immediately charge the unit for more than 24 hours.
CONTENTS 1. Introduction.…………………………………………………………..………. 2. Guidelines for Use ………………………………………………………….. 3. Precautions for Using Rechargeable Appliances ……………… 4. Product Description ……………………………………………………….. 5. Product Features ……………………………………………………………. 6. Installation / Set-up………………………………………………………... 7. Installing Additional Battery Pods …………………………………. 8. Operation ………………………………………………………………………. 9. Operating the PV Solar Input …………………………………….……. 10. Understanding the Error Codes ………………………………………. 11.
1. INTRODUCTION Thank you for purchasing the Solar Generator 1800. With our state of the art, easy to use design, this product will offer you reliable service providing a solar-powered rechargeable power source for your home, cabin, or campsite. With its highly technical design and comprehensive features, the Solar Generator 1800 will provide you with a simple yet effective user experience as you learn to generate your own power. The unit can run many AC and DC-powered appliances whenever you need power.
. PRODUCT FEATURES Inverter (Base) Unit 4 3 7 15 14 1 11 10 16 6 5 2 6 13 12 8 Rear View 9 Front View 17 19 18 Rear View 20 21 Front View Feature Description Feature 1 Power Button turns Solar Generator 1800 on and off when utility power is not available. • Press for about a second until a beep sound occur, unit is turned on.
. INSTALLATION / SET-UP WARNING: FAILURE TO FOLLOW THESE INSTRUCTIONS CAN DAMAGE THE UNIT. WARNING: SHOCK HAZARD If the input plug is connected and utility power is present, the outlets will be energized. The front panel ON/OFF button will not turn these outlets off.
DISCONNECT SOLAR PANEL FROM UNIT: Cover the solar panel with an opaque sheet or flip the solar panel with the solar cells facing down on a flat surface to minimize the output voltage to zero volts. Verify the Solar charge indicator is off. Disconnect the solar cable connector from the solar input port of the unit. Gently squeeze the locking tabs on the sides of the plug while pulling it out to release the plug.
GENERAL NOTES ON SOLAR PANEL USE AND MAINTENANCE Keep the solar panel clean. An accumulation of dirt, dust, or mildew will cause poor performance as the dirt will block the light from the panel. Use only mild soap and water to clean the panel. Caustic or abrasive cleaners or solvents will damage the panel’s surface. Do not use any glass cleaners with ammonia as these will also damage the panel. You can maximize the performance of the solar panel by “following” the sun as it moves across the sky.
8. OPERATION OPERATING THE MAIN UNIT OPERATING MODE (MAIN UNIT) STATUS LED INDICATIONS NORMAL OPERATION: Utility power is available and “Utility/Backup Power/ Fault” LED is unit is turned on. The internal battery is fully charged. solid green. Screen shows “FUL.” RECHARGING INTERNAL BATTERY: Unit is recharging its internal battery after utility power has been restored. Internal fan is running. “Utility/Backup Power/ Fault” LED is green. Screen shows “CHG” and shows “FUL” when internal battery is full.
. UNDERSTANDING THE ERROR CODES ERROR CONDITION CODE CORRECTIVE ACTION F_1 Inverter has sensed input under voltage and has shutdown Recharge battery immediately and restart unit F_2 Inverter has sensed input over voltage and has shutdown Check battery voltage or if any external charger is connected to the battery pod. Correct input and restart unit. F_3 Inverter output has sensed overload or short circuit and was shutdown Check load connected to the output.
12. BATTERY REPLACEMENT The unit contains an 80AH battery. A qualified battery/electronic technician is required to replace the battery. To replace the battery, please contact customer service for details. 13.
14. SPECIFICATIONS NOTE: Specifications are subject to change without notice. INVERTER SPECIFICATION: INTERNAL AC CHARGER SPECIFICATION: Output Current/Power: 12A/1440W continuous 15A/1800W maximum 2880W peak Surge Power: Output Voltage: Output Waveform: Peak Efficiency: 5 ADC Output Voltage (Absorption/Float): Recharge Voltage: Efficiency: 14.8/13.
15. OPTIONS FOR EXPANSION & ACCESSORIES This Solar Generator 1800 Kit is a modular design. Battery capacity can easily be extended with multiple standalone battery pods through a pre-wired built-in internal connector located at the back of the unit. Additional solar panels can be purchased to improve battery charging time (1 for each additional battery pod).
16. UNDERSTANDING SOLAR ELECTRIC POWER Understanding the specifications and operational characteristics of your solar powered electrical back-up system will help you obtain the maximum utilization and enjoyment from it. All solar electric power systems depend on batteries to supply the bulk of the power delivered to the user. The primary function of the solar panels is to charge the batteries. While some small electrical loads may be supplied directly from a solar panel this is usually not practical.