Installation Guide

Page 8 of 12
DC Output work mode
1.Press the [Down] button to ON/OFF load manully at main display.
2.Selecting work mode as below:
(24H) load output 24hours
(1-23H) load on after sunset and closed after setting hours
(0H) Dusk to dawn
Press MENU to browse different interface.
In interface2-5,long press MENU to enter setting,and using[UP] [DOWN] to set the parameter,
long press MENU again to exit.
long press [DOWN] to restore parameter.
1 2 3
6 5 4
Main display Float voltage LVR
DC output
(Low Voltage Recovery)
LVD
DC output
(Low Voltage Disconnect)
DC output
work mode
Battery type
Situation
Charge Icon Not On When Sunny
Load Icon Off
Load Icon Flashing
Power Off
Mode setting wrong
Battery low
Over load Reduce load power
Auto reconnectShort circuit protection
Battery low Check battery
Check and reconnectReverse connection
Solar panel opened or reversed connect
Reconnect
Adjust setting
Charge battery
Probable cause
Solution
Trouble shooting
Press to
increase value
Press to
increase value
Switching display,
or to enter/exit setting
by long Press.
LCD Display / Setting
Voltage
Hour
Amper
Load
Output
Display
Solar Panel
Charge
ON: equalation/buck
Battery
Flicking: Float