Use and Care Guide
1. To connect 2 Solar Panels together simply remove the SAE connector at the end of each Solar
Panel to reveal at least 2 inches of bare wiring.
2. Once the two wires are exposed they can be connected together by either twisting the wires
together or by using solder. When connecting the wires always ensure the correct polarity is
observed, Negative (- Black) to Negative and Positive(+ Red) to positive.
3. Once the wires are connected they can be place in/on the correct terminals of your charge
controller.
4. Once the wires have been placed on their terminaIs correctly ensure the connection is safe and
secure and that the bare wires cannot come into contact with each other. This can be done by
using insulation tape or electrical tape that can be wrapped around the wires to stop the coming
into contact with one another.
Note: If the Solar Panel wires short while being connected to the Charge Controller it may cause
irreparable damage. Removing the SAE connector will not have the warranty on Solar Panels.
You can also contact nature power for a 2 in 1 SAE cable for 2 panels fast connected.
Selecting the correct Battery
We do not offer batteries. However, please choose a 12 Volt rechargeable battery. Do not attempt to
recharge non-rechargeable batteries. 6 Volt battery configurations may also be used if connected in
series (Negative to Positive). You may choose a Sealed Lead Acid battery, a Gel-Cell or a Deep
Cycle 12 Volt battery. Batteries come in all different sizes, Please converse with your battery dealer
for more information on which type of battery you should use for your system. Note your solar panel
amperage rating when selecting your battery size.
Additional 12V DC Batteries
Addition batteries may be desired for extra electrical storage.
For 12 Volt battery bank configurations; make sure your batteries are connected in parallel (Positive
to Positive and Negative to Negative)
v From the charge controller attach the red battery clamp to the red terminal of the first battery in
the bank, matching the polarities, positive to positive.
v Then connect the black alligator clamp to the black terminal of the second or late battery in the
bank, again matching polarities, negative to negative. This will ensure an equal charging across
both or all batteries.
Operating Instruction
Additional Solar Panels
Page 7 of 10