V1.1-M 1Jun2018 Marine Grade 2000W 24 Volt Wind Generator User Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious personal injury.
Contents 1. Getting started 1 2. Safety instruction 1 3. Installation siting 3 4. Specifications 4 5. Part name 5 6. Assembling module 6-1 Verify the following upon purchase 6-2 Assembly procedure 6-3 Attaching to pole 5 5 6 7 7.Connecting the system 7-1 Before connecting 7-2 Length of the extension cable that leads from the wind generator to the battery 7-3 Stop the wind turbine 7-4 Connecting the wind generator output cable extension 7-5 Connection example 7-6 Connecting the System 8 8 8 8.
1.Getting Started Congratulations on the purchase of your new 2000W– 24V Nature Power Wind Turbine. This manual will provide you with a good basic understanding of the operation and maintenance of this unit. In the unlikely event that this product does not function properly, prohibit all persons except for trained technicians from handling its internal systems and contact either the dealer from whom you purchased it or Nature Power customer service department: Tel. 1-800-588-0590.
CAUTION This symbol indicates information that could result in death, severe injury, or damage to limited property if ignored. CAUTION Be aware that failure to use the product in the manner indicated by may, depending on circumstances, also have severe consequences. All of the symbols described above indicate important safety information. Obey all safety information when using this product. Safety information is indicated as shown below.
Do not pull on, excessively bend, or attempt to modify the wires/cables of the wind generator. Doing so could result in cord damage, electrocution, or fire. Never attempt to disassemble or modify the wind generator. Doing so could result in electrocution, fire, or wind generator malfunction. Due to conditions of use, this system may not continuously supply stable electrical power.
4.Specifications Wind Turbine Type Horizontal axis, up-wind UPC code Rotor Diameter 839290007075 Weight Mount Diameter Number Blades 18kg(38lbs) 1776mm(69.9'') 48.
5.Part name 012-Tail screw 011-Blades nut 001-Tail 002-Body(Bulit-in Controller) 003-Yaw Shaft Cover 004-Insulator 005-Yaw shaft Bolt 007-Hub 09Jam nut 013-hex key (8mm/6mm) 006-Blades(3) 014-instruction manual 010-Nose Cone 008-Blades bolt(6) 010 6. Assembling module 6-1 Verify the following upon purchase Tail Unit The body Unit and the tail is packed in the same box.
Body Unit Blades, Hub, and Nuts 6-2 Assembly procedure 1 2 3 4 Assembly procedure Attach the body to the pole Attach the tail to the body Assemble the rotor(assembe the blades to Hub) Attach the rotor assembly to the body. Tail 2 4 Rotor Body(Bulit-in Controller) 1 3 Mast on top of the tower (outer diameter is 1.9 inches [48.6mm]) thickness more than 3/16 inches (5mm). Use 1½ inches (schedule 80steel) pipe. For tightening the main-shaft. Should be able to tighten up to 29.5±1.5ft.lb (40±2N.
WARNING Failure to observe these safety instructions may result in a severe accident or damage to the wind generator or other parts of the system. Do not place the wind generator body upside down or inclined during installation or maintenance. Water (rain, snow) can leak inside the body joint gap and cause damage to the turbine. During installation when the body is upside down or inclined and has the possibility of getting wet, put a cover over the body.
7.Connecting the System 7-1 Before connecting The 24V model is used as a standalone system (off-grid system). A 24V battery is required for the system. The following explains how to connect the wind generator power cable (approximately 20inches [500mm] long) and provides a typical example of a wind turbine system connection. Important *Pay attention to the + and – terminals when connecting the power cable to the battery. Reverse connection will cause serious damage.
7-4 Connecting the wind generator output cable extension A total of six cables extend from the wind turbine: four power cables and two data communication cables. * Each cable is 500mm long. The white data transmission cable is +(positive) The 2 black AWG#10 (5.5mm²) power cables are-(negative) The blue date transmission cable is-(negative) mp loa d Stop switch Du The 2 red AWG#10 (5.
only when the turbine is first connected to the battery (with the capacitor discharged) or at the moment the charged capacitor is short circuited by the blade switch in the “Brake” position. CAUTION This manual is intended for individuals who have the knowledge and technical skills needed to work with batteries and electrical wiring. If the wind generator is used in an inappropriate configuration or wired incorrectly, its use could cause a severe accident and damage the system, including this product.
Operating StatusTable Mode Start/Restart Indicator Light No light Solid green Normal operation Flashing red Voltage protection solid red Other Cause Generating power. (Wind speed range: 3 to 12 m/s, 11 to 43KPH, 6.7 to 27MPH) Next Operation Starts in normal operating mode When the rotor is rotating at 0 to 999 rpm Generating power at The rpm is limited Flashing green controlled rpm. (Wind to 1000 rpm.
be the same type, chemical, age and capacity (in Ah). You can connect several 24V groups in parallel to increase the battery bank capacity in Ah. However the capacity of a 24V group is the same of each single battery in series within the group (no Ah increment). Each 24V group can have different capacities. When connected in parallel the total capacity is the sum of all individual 24V group capacities.
meets it). The total tower height must be sufficient to prevent accidents with body or structures. •The tower must withstand horizontal wind pressure of 231lbf(105kgf) (at a wind speed of 49.2m/s, 110mph,177KPH). •If unsure please consult with your local tower contractor for details. 9-3 Cable Diameter Sizes: To select the appropriate cables gauge, measure the distance between the turbine and the batteries. Make sure to include the height of the tower. Please refer to the following wire gauge chart.
•Connect the inverter and all other devices directly to the battery bank posts. Never use the same wires of the turbine to connect other DC devices (sources or loads), Each device has to be connected directly to the battery bank posts with its own wires. If the battery bank posts are so crowded with wires, try to use a junction bar on the posts. 9-5 Grounding: We recommended installing a 1 or 2 ft (30 or 60cm)long grounding jumper between the wind turbine bracket hex bolts and the mast.
FEET 1-500ft 500-1,000ft 1,000-2,000ft 2,000-3,000ft 3,000-4,000ft 4,000-5,000ft 5,000-6,000ft 6,000-7,000ft 7,000-8,000ft 8,000-9,000ft 9,000-10,000ft METER 0-150m 150-300m 300-600m 600-900m 900-1,200m 1,200-1,500m 1,500-1,800m 1,800-2,100m 2,100-2,400m 2,400-2,700m 2,700-3,000m OUTPUT POWER 100% 97% 94% 91% 88% 85% 82% 79% 76% 73% 70% 11.
12.
The turbine (especially its tail) is yawing continuously Every time the rotor shaft begins to spin, it stops suddenly with a strong brake action Swirling air because of turbulence Open circuit in the DC connection between the turbine and the battery bank If the Indicator light is solid red The rotor remains stopped even with high wind speed condition If the Indicator light is off The turbine works at controlled rpm often, with the battery bank voltage below the normal maximum of 28.
The battery bank voltage increases easily and fast, forcing the unit to activate the controlled rpm mode and even the complete stop very often The Indicator Light status is flashing red (controlled rpm mode of operation) Normal if the battery bank is full charged and there is not/ low power consumption from the loads connected to the battery bank.