Installation Guide
7-2 Length of the extension cable that leads from the wind generator
to the battery
7.Connecting the System
7-1 Before connecting
Important
* Pay attention to the + and – terminals when connecting the power cable
to the battery. Reverse connection will cause serious damage.
(Be aware that any damage to this product caused by improper connection
is NOT covered by the warranty. Connect the cables to the correct terminals).
The wind generator is designed to use double wires with a length of 15m
(49ft) and a gauge of AWG #8 (8mm²) between the wind generator and the
batteries. However you can select the appropriate wire gauge according to
the distance. Please check section 9 (“Considerations when choosing
Peripheral Materials/Devices”). Make sure to include the height of the tower.
The 24V model is used as a standalone system (off-grid system).
A 24V battery is required for the system. The following explains
how to connect the wind generator power cable (approximately 20inches
[500mm] long) and provides a typical example of a wind turbine system
connection.
Page 10 of 20
Important
The wind turbine is 24V type, please connect to 24V battery bank.
7-3 Stop the wind turbine
To ensure safety, the wind generator is equipped with an emergency stop
feature. In the event of an emergency stop, the wind generator’s power
supply must be shut off in an approximate 20 seconds before being restarted.
the stop switch is on the dump load box panel. Once turn the switch to the stop
position, the wind turbine will stop within 20 seconds.
If the wind turbine is not in the connection with the battery bank, please make
sure the stop switch in “stop” position.
Important
Before connect the batteries, the electric relays will be always in the off condition,
at the moment, the wind turbine can not spin, so please do not rotate the wind turbine.
Before charging, please make sure each connection is on good condition, especially
the dump load box and battery bank.
When the turbine and the batteries are connected well, the electric relays will be open
automatically, now it is ok to start up the wind turbine.