Operations and Maintenance Manual
Table Of Contents
- Release control record
- Section 1: Description
- Section 2: Operating the transmitter
- User Interfaces
- Viewing Transmitter Log
- Viewing AUI Tool Menu Panels
- Viewing Real-Time Meters
- Managing Presets
- Enabling Remote Control
- Resetting Alarms
- Viewing Transmitter Status
- System Settings
- System Settings - Front Panel UI
- Setting User Accounts
- User Settings - AUI
- User Settings - Front Panel UI
- Configuring Remote Inputs and Outputs
- Scheduler
- Audio Player
- Enabling and Operating the Orban Audio Processor
- Figure 2-1 : VS Transmitter Front Panel Display Menu Tree (Sheet 1 of 2)
- Figure 2-2 : VS Transmitter Front Panel Display Menu Tree - Edit Presets (Sheet 2 of 2)
- Figure 2-3 : VS Transmitter AUI Flow Diagram
- Section 3: Routine maintenance
- Section 4: Non-standard maintenance
- Section 5: List of terms
VS300 Operations and Maintenance Manual Operating the transmitter
Page 2-154 Issue 10.0 2019-01-18
Setting Pilot Sample Level
From the front panel UI, you can set the level of the sine-wave pilot sample that is applied to
the
PILOT SAMPLE OUT (A1J4A)
BNC connector on the rear of the controller (A4). To view the
Pilot Sample
screen, select
User Settings -> Pilot Sample
from the
Main Menu
(see Figure 2.130
on page 2-154).
Figure 2.130: Pilot Sample Screen
Use the up and down buttons to edit the pilot sample level between 0 and 2.70 V peak-to-peak
(in 0.01 V increments). Press the accept (checkmark) button to save the change. Press cancel (
X
)
to discard changes and return to the previous menu.
Note:
Setting the pilot sample is only available using the front panel UI.