VS300 Operations and Maintenance Manual Operating the transmitter
Page 2-168 Issue 10.0 2019-01-18
Analog Outputs
There are four analog outputs - forward power, reflected power, average PA voltage and total
PA current - that can be remotely monitored (see Figure 2.143). These outputs are factory
defined parameters (cannot be changed to other parameters), however their scaling can be
configured to reflect the output voltage that yields a full-scale deflection.
The values associated with each of these fixed meters are of a linear nature so that changes
made to the
Sample Full Scale
field (allowable range is 1- 6 V, defaulted to 6 V) will be reflected
in the other fields according to the following equation:
(Meter Value/Meter Full Scale) x Sample Full Scale = Sample Voltage
Press
Apply
to activate changes. Press
Cancel
to discard changes.
Figure 2.143: Analog Outputs
Note:
The Sample Voltage reading reflects the value that can be measured at the
associated remote analog output pin for the given Meter Value. See the VS series
transmitter Pre-installation Manual for actual remote analog output pin
assignments.