Operations and Maintenance Manual
Table Of Contents
- Release control record
- Section 1: Description
- Section 2: Operating the transmitter
- User Interfaces
- Viewing Transmitter Log
- Viewing AUI Tool Menu Panels
- Viewing Real-Time Meters
- Managing Presets
- Enabling Remote Control
- Resetting Alarms
- Viewing Transmitter Status
- System Settings
- System Settings - Front Panel UI
- Setting User Accounts
- User Settings - AUI
- User Settings - Front Panel UI
- Configuring Remote Inputs and Outputs
- Scheduler
- Audio Player
- Enabling and Operating the Orban Audio Processor
- Figure 2-1 : VS Transmitter Front Panel Display Menu Tree (Sheet 1 of 2)
- Figure 2-2 : VS Transmitter Front Panel Display Menu Tree - Edit Presets (Sheet 2 of 2)
- Figure 2-3 : VS Transmitter AUI Flow Diagram
- Section 3: Routine maintenance
- Section 4: Non-standard maintenance
- Section 5: List of terms
VS300 Operations and Maintenance Manual Operating the transmitter
Page 2-168 Issue 10.0 2019-01-18
Analog Outputs
There are four analog outputs - forward power, reflected power, average PA voltage and total
PA current - that can be remotely monitored (see Figure 2.143). These outputs are factory
defined parameters (cannot be changed to other parameters), however their scaling can be
configured to reflect the output voltage that yields a full-scale deflection.
The values associated with each of these fixed meters are of a linear nature so that changes
made to the
Sample Full Scale
field (allowable range is 1- 6 V, defaulted to 6 V) will be reflected
in the other fields according to the following equation:
(Meter Value/Meter Full Scale) x Sample Full Scale = Sample Voltage
Press
Apply
to activate changes. Press
Cancel
to discard changes.
Figure 2.143: Analog Outputs
Note:
The Sample Voltage reading reflects the value that can be measured at the
associated remote analog output pin for the given Meter Value. See the VS series
transmitter Pre-installation Manual for actual remote analog output pin
assignments.